Abstract
Buffer function of polyimide layer by drop test is discussed. The drop impact was calculated with a finite element analysis. It was found the factors of polyimide thickness and modulus have contributions to stress responses.
Original language | English |
---|---|
DOIs | |
Publication status | Published - 2013 Jan 1 |
Event | 2013 3rd IEEE CPMT Symposium Japan, ICSJ 2013 - Kyoto, Japan Duration: 2013 Nov 11 → 2013 Nov 13 |
Conference
Conference | 2013 3rd IEEE CPMT Symposium Japan, ICSJ 2013 |
---|---|
Country/Territory | Japan |
City | Kyoto |
Period | 13/11/11 → 13/11/13 |
Keywords
- Drop Test
- Finite Element Analysis
- Polyimide
ASJC Scopus subject areas
- Electrical and Electronic Engineering