A method for estimating 3-D nuclear parameters using an image taken from a hepatic histopathological section

Research output: Chapter in Book/Report/Conference proceedingConference contribution

1 Citation (Scopus)

Abstract

A method is described for estimating the 3-D nuclear parameters (3-D nuclear density and average and variance of nuclear radii) from one microscopic image taken from one hepatic histopathological section. The method estimates the probability densities of the parameters, so, not only the expected values but also the confidence intervals, which are important in actual diagnosis, are calculated. Since only one image, which is taken from one histopathological section used in daily diagnosis, is needed, it is convenient for pathologists to use this method. A graphical user interface makes the method easy to use.

Original languageEnglish
Title of host publicationAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
Pages3761-3764
Number of pages4
DOIs
Publication statusPublished - 2007
Event29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07 - Lyon
Duration: 2007 Aug 232007 Aug 26

Other

Other29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07
CityLyon
Period07/8/2307/8/26

Fingerprint

Graphical user interfaces

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Takahashi, M., Yoshimi, T., & Nakano, M. (2007). A method for estimating 3-D nuclear parameters using an image taken from a hepatic histopathological section. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings (pp. 3761-3764). [4353150] https://doi.org/10.1109/IEMBS.2007.4353150

A method for estimating 3-D nuclear parameters using an image taken from a hepatic histopathological section. / Takahashi, Masanobu; Yoshimi, Takashi; Nakano, Masayuki.

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 2007. p. 3761-3764 4353150.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Takahashi, M, Yoshimi, T & Nakano, M 2007, A method for estimating 3-D nuclear parameters using an image taken from a hepatic histopathological section. in Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings., 4353150, pp. 3761-3764, 29th Annual International Conference of IEEE-EMBS, Engineering in Medicine and Biology Society, EMBC'07, Lyon, 07/8/23. https://doi.org/10.1109/IEMBS.2007.4353150
Takahashi M, Yoshimi T, Nakano M. A method for estimating 3-D nuclear parameters using an image taken from a hepatic histopathological section. In Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 2007. p. 3761-3764. 4353150 https://doi.org/10.1109/IEMBS.2007.4353150
Takahashi, Masanobu ; Yoshimi, Takashi ; Nakano, Masayuki. / A method for estimating 3-D nuclear parameters using an image taken from a hepatic histopathological section. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 2007. pp. 3761-3764
@inproceedings{539c8b825cd14d01a46849ea4cef9db2,
title = "A method for estimating 3-D nuclear parameters using an image taken from a hepatic histopathological section",
abstract = "A method is described for estimating the 3-D nuclear parameters (3-D nuclear density and average and variance of nuclear radii) from one microscopic image taken from one hepatic histopathological section. The method estimates the probability densities of the parameters, so, not only the expected values but also the confidence intervals, which are important in actual diagnosis, are calculated. Since only one image, which is taken from one histopathological section used in daily diagnosis, is needed, it is convenient for pathologists to use this method. A graphical user interface makes the method easy to use.",
author = "Masanobu Takahashi and Takashi Yoshimi and Masayuki Nakano",
year = "2007",
doi = "10.1109/IEMBS.2007.4353150",
language = "English",
isbn = "1424407885",
pages = "3761--3764",
booktitle = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",

}

TY - GEN

T1 - A method for estimating 3-D nuclear parameters using an image taken from a hepatic histopathological section

AU - Takahashi, Masanobu

AU - Yoshimi, Takashi

AU - Nakano, Masayuki

PY - 2007

Y1 - 2007

N2 - A method is described for estimating the 3-D nuclear parameters (3-D nuclear density and average and variance of nuclear radii) from one microscopic image taken from one hepatic histopathological section. The method estimates the probability densities of the parameters, so, not only the expected values but also the confidence intervals, which are important in actual diagnosis, are calculated. Since only one image, which is taken from one histopathological section used in daily diagnosis, is needed, it is convenient for pathologists to use this method. A graphical user interface makes the method easy to use.

AB - A method is described for estimating the 3-D nuclear parameters (3-D nuclear density and average and variance of nuclear radii) from one microscopic image taken from one hepatic histopathological section. The method estimates the probability densities of the parameters, so, not only the expected values but also the confidence intervals, which are important in actual diagnosis, are calculated. Since only one image, which is taken from one histopathological section used in daily diagnosis, is needed, it is convenient for pathologists to use this method. A graphical user interface makes the method easy to use.

UR - http://www.scopus.com/inward/record.url?scp=57649202273&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=57649202273&partnerID=8YFLogxK

U2 - 10.1109/IEMBS.2007.4353150

DO - 10.1109/IEMBS.2007.4353150

M3 - Conference contribution

C2 - 18002816

AN - SCOPUS:57649202273

SN - 1424407885

SN - 9781424407880

SP - 3761

EP - 3764

BT - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

ER -