A new fluorescence microscopy for tomographic observation of microcirculation by using dual-beam slit laser illumination

Masahiro Shibata, Takashi Kawamura, Mitra Sohirad, Akira Kamiya

Research output: Contribution to journalArticle

8 Citations (Scopus)

Abstract

By designing a new epi-illumination system with dual slit laser beams, we have developed a fluorescence microscope for tomographic observations of in vivo microcirculation. Two beams of an Argon ion laser were converted into thin slit beams of thickness 28 to 60 μm by optical lenses and were illuminated onto tissue to intersect at the focal plane of the objective. The fluorescent light emitted from a FITC tracer by this cross-illumination was picked up by the microscope through a filter, with no 'out of focus' noise from the tracer above and below the crossing zone. The results of in vitro experiments by using glass micropipettes (20-80 μm i.d.) filled with FITC-dextran and skeletal muscle tissue certified uniform tracer excitation in the crossing zone and the augmentation of the beam thickness due to light scattering in the tissue to be 1.7 and 2.5 times at depths of 100 and 200 μm from the surface, respectively. In vivo tests in the rabbit tenuissimus muscle revealed that this system can realize microvasculature tomography, with adequate vertical zone selectivity and spatial resolution to reconstruct its three-dimensional mapping, and long-term monitoring of tracer leakage from a single capillary to the surrounding tissue, with sufficient quantitative reliability to determine the capillary permeability and its heterogeneity along the channel.

Original languageEnglish
Pages (from-to)300-314
Number of pages15
JournalMicrovascular Research
Volume49
Issue number3
DOIs
Publication statusPublished - 1995
Externally publishedYes

Fingerprint

Microcirculation
Fluorescence microscopy
Laser beams
Lighting
Tissue
Muscle
Microscopes
Fluorescein-5-isothiocyanate
Argon
Light scattering
Tomography
Lenses
Fluorescence
Ions
Glass
Lasers
Monitoring
Experiments

ASJC Scopus subject areas

  • Biochemistry
  • Cardiology and Cardiovascular Medicine
  • Cell Biology

Cite this

A new fluorescence microscopy for tomographic observation of microcirculation by using dual-beam slit laser illumination. / Shibata, Masahiro; Kawamura, Takashi; Sohirad, Mitra; Kamiya, Akira.

In: Microvascular Research, Vol. 49, No. 3, 1995, p. 300-314.

Research output: Contribution to journalArticle

@article{de4828566f6d4d6cb01fcbe21cfa04a5,
title = "A new fluorescence microscopy for tomographic observation of microcirculation by using dual-beam slit laser illumination",
abstract = "By designing a new epi-illumination system with dual slit laser beams, we have developed a fluorescence microscope for tomographic observations of in vivo microcirculation. Two beams of an Argon ion laser were converted into thin slit beams of thickness 28 to 60 μm by optical lenses and were illuminated onto tissue to intersect at the focal plane of the objective. The fluorescent light emitted from a FITC tracer by this cross-illumination was picked up by the microscope through a filter, with no 'out of focus' noise from the tracer above and below the crossing zone. The results of in vitro experiments by using glass micropipettes (20-80 μm i.d.) filled with FITC-dextran and skeletal muscle tissue certified uniform tracer excitation in the crossing zone and the augmentation of the beam thickness due to light scattering in the tissue to be 1.7 and 2.5 times at depths of 100 and 200 μm from the surface, respectively. In vivo tests in the rabbit tenuissimus muscle revealed that this system can realize microvasculature tomography, with adequate vertical zone selectivity and spatial resolution to reconstruct its three-dimensional mapping, and long-term monitoring of tracer leakage from a single capillary to the surrounding tissue, with sufficient quantitative reliability to determine the capillary permeability and its heterogeneity along the channel.",
author = "Masahiro Shibata and Takashi Kawamura and Mitra Sohirad and Akira Kamiya",
year = "1995",
doi = "10.1006/mvre.1995.1026",
language = "English",
volume = "49",
pages = "300--314",
journal = "Microvascular Research",
issn = "0026-2862",
publisher = "Academic Press Inc.",
number = "3",

}

TY - JOUR

T1 - A new fluorescence microscopy for tomographic observation of microcirculation by using dual-beam slit laser illumination

AU - Shibata, Masahiro

AU - Kawamura, Takashi

AU - Sohirad, Mitra

AU - Kamiya, Akira

PY - 1995

Y1 - 1995

N2 - By designing a new epi-illumination system with dual slit laser beams, we have developed a fluorescence microscope for tomographic observations of in vivo microcirculation. Two beams of an Argon ion laser were converted into thin slit beams of thickness 28 to 60 μm by optical lenses and were illuminated onto tissue to intersect at the focal plane of the objective. The fluorescent light emitted from a FITC tracer by this cross-illumination was picked up by the microscope through a filter, with no 'out of focus' noise from the tracer above and below the crossing zone. The results of in vitro experiments by using glass micropipettes (20-80 μm i.d.) filled with FITC-dextran and skeletal muscle tissue certified uniform tracer excitation in the crossing zone and the augmentation of the beam thickness due to light scattering in the tissue to be 1.7 and 2.5 times at depths of 100 and 200 μm from the surface, respectively. In vivo tests in the rabbit tenuissimus muscle revealed that this system can realize microvasculature tomography, with adequate vertical zone selectivity and spatial resolution to reconstruct its three-dimensional mapping, and long-term monitoring of tracer leakage from a single capillary to the surrounding tissue, with sufficient quantitative reliability to determine the capillary permeability and its heterogeneity along the channel.

AB - By designing a new epi-illumination system with dual slit laser beams, we have developed a fluorescence microscope for tomographic observations of in vivo microcirculation. Two beams of an Argon ion laser were converted into thin slit beams of thickness 28 to 60 μm by optical lenses and were illuminated onto tissue to intersect at the focal plane of the objective. The fluorescent light emitted from a FITC tracer by this cross-illumination was picked up by the microscope through a filter, with no 'out of focus' noise from the tracer above and below the crossing zone. The results of in vitro experiments by using glass micropipettes (20-80 μm i.d.) filled with FITC-dextran and skeletal muscle tissue certified uniform tracer excitation in the crossing zone and the augmentation of the beam thickness due to light scattering in the tissue to be 1.7 and 2.5 times at depths of 100 and 200 μm from the surface, respectively. In vivo tests in the rabbit tenuissimus muscle revealed that this system can realize microvasculature tomography, with adequate vertical zone selectivity and spatial resolution to reconstruct its three-dimensional mapping, and long-term monitoring of tracer leakage from a single capillary to the surrounding tissue, with sufficient quantitative reliability to determine the capillary permeability and its heterogeneity along the channel.

UR - http://www.scopus.com/inward/record.url?scp=0029017773&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0029017773&partnerID=8YFLogxK

U2 - 10.1006/mvre.1995.1026

DO - 10.1006/mvre.1995.1026

M3 - Article

C2 - 7643751

AN - SCOPUS:0029017773

VL - 49

SP - 300

EP - 314

JO - Microvascular Research

JF - Microvascular Research

SN - 0026-2862

IS - 3

ER -