Abstract
Nowadays, medical accidents increase in Japanese patient environment. Especially, misidentification of the patients occurred in operation room of higher level hospitals. It is considered that the great deals of accidents are due to mistakes by nurse. However, the accidents are prevented by management of patients. If a suitable patient identification system is developed, the accidents are prevented. In this study, new patient identification system using battery less LF band RFID(Radio Frequency Identification) is proposed. In the method, battery less RFID tag is attached to patient. In operation room, patient is identified before operation using the proposed system. However, identification distance of RFID is small. It is important that extension of the distance. In this study antennas of RFID tag and sensor are designed. Two types of tag are proposed. One of them is set on wristband. An antenna for the tag is designed as a circular shape with 30mm in diameter. The other one is shaped like a necklace. The ant nna is also designed 220mm, 240mm and 260mm in diameter. Using necklace type new antenna, sufficient identification distance for detection of the tag in the operation room is realized. The patient identification is realized using the proposed system.
Original language | English |
---|---|
Pages (from-to) | 246-254 |
Number of pages | 9 |
Journal | IEEJ Transactions on Electronics, Information and Systems |
Volume | 123 |
Issue number | 2 |
DOIs | |
Publication status | Published - 2003 Jan |
Externally published | Yes |
Keywords
- battery less tag
- LF band RFID
- medical accident
- misidentificatioii of patients
ASJC Scopus subject areas
- Electrical and Electronic Engineering