Automatic detection method of muscle fiber movement as revealed by ultrasound images

Tasuku Miyoshi, Tomohiko Kihara, Hiroyuki Koyama, Shinichirou Yamamoto, Takashi Komeda

Research output: Contribution to journalArticle

14 Citations (Scopus)

Abstract

The objective of this study was to develop a method of muscle structure measurement based on the automatic analysis of muscle fibers, proximal fascias, and distal aponeurosis movements as revealed by a time-series of ultrasound images. This method was designed to detect changes in the length of muscle fiber movements, and its validity was demonstrated in a time-series of muscle movement, slow ankle dorsiflexion (10°/s), by comparison to manual measurement. The results showed that, when this method was used, the changes in the length of the muscle fiber under slow muscle movement were smaller than those in manual operations by novice individuals. However, with the proposed method, it was possible to obtain a sufficient degree of validity and reliability for the changes in the length of the muscle fiber length compared with those in manual operations, since the correlation coefficients exceeded 0.8 which was tested by the linear regression. The proposed method suggests that automation reduces the errors caused by manual operations and makes the processing of data possible in an acceptable amount of time.

Original languageEnglish
Pages (from-to)558-564
Number of pages7
JournalMedical Engineering and Physics
Volume31
Issue number5
DOIs
Publication statusPublished - 2009 Jun

Fingerprint

Muscle
Ultrasonics
Fibers
Time series
Linear regression
Automation
Processing

Keywords

  • Automatic analysis
  • Manual operation
  • Muscle fiber movements
  • Ultrasound images

ASJC Scopus subject areas

  • Biomedical Engineering
  • Biophysics

Cite this

Automatic detection method of muscle fiber movement as revealed by ultrasound images. / Miyoshi, Tasuku; Kihara, Tomohiko; Koyama, Hiroyuki; Yamamoto, Shinichirou; Komeda, Takashi.

In: Medical Engineering and Physics, Vol. 31, No. 5, 06.2009, p. 558-564.

Research output: Contribution to journalArticle

Miyoshi, Tasuku ; Kihara, Tomohiko ; Koyama, Hiroyuki ; Yamamoto, Shinichirou ; Komeda, Takashi. / Automatic detection method of muscle fiber movement as revealed by ultrasound images. In: Medical Engineering and Physics. 2009 ; Vol. 31, No. 5. pp. 558-564.
@article{ba4995a3cdec44c88522098813f4726d,
title = "Automatic detection method of muscle fiber movement as revealed by ultrasound images",
abstract = "The objective of this study was to develop a method of muscle structure measurement based on the automatic analysis of muscle fibers, proximal fascias, and distal aponeurosis movements as revealed by a time-series of ultrasound images. This method was designed to detect changes in the length of muscle fiber movements, and its validity was demonstrated in a time-series of muscle movement, slow ankle dorsiflexion (10°/s), by comparison to manual measurement. The results showed that, when this method was used, the changes in the length of the muscle fiber under slow muscle movement were smaller than those in manual operations by novice individuals. However, with the proposed method, it was possible to obtain a sufficient degree of validity and reliability for the changes in the length of the muscle fiber length compared with those in manual operations, since the correlation coefficients exceeded 0.8 which was tested by the linear regression. The proposed method suggests that automation reduces the errors caused by manual operations and makes the processing of data possible in an acceptable amount of time.",
keywords = "Automatic analysis, Manual operation, Muscle fiber movements, Ultrasound images",
author = "Tasuku Miyoshi and Tomohiko Kihara and Hiroyuki Koyama and Shinichirou Yamamoto and Takashi Komeda",
year = "2009",
month = "6",
doi = "10.1016/j.medengphy.2008.11.004",
language = "English",
volume = "31",
pages = "558--564",
journal = "Medical Engineering and Physics",
issn = "1350-4533",
publisher = "Elsevier BV",
number = "5",

}

TY - JOUR

T1 - Automatic detection method of muscle fiber movement as revealed by ultrasound images

AU - Miyoshi, Tasuku

AU - Kihara, Tomohiko

AU - Koyama, Hiroyuki

AU - Yamamoto, Shinichirou

AU - Komeda, Takashi

PY - 2009/6

Y1 - 2009/6

N2 - The objective of this study was to develop a method of muscle structure measurement based on the automatic analysis of muscle fibers, proximal fascias, and distal aponeurosis movements as revealed by a time-series of ultrasound images. This method was designed to detect changes in the length of muscle fiber movements, and its validity was demonstrated in a time-series of muscle movement, slow ankle dorsiflexion (10°/s), by comparison to manual measurement. The results showed that, when this method was used, the changes in the length of the muscle fiber under slow muscle movement were smaller than those in manual operations by novice individuals. However, with the proposed method, it was possible to obtain a sufficient degree of validity and reliability for the changes in the length of the muscle fiber length compared with those in manual operations, since the correlation coefficients exceeded 0.8 which was tested by the linear regression. The proposed method suggests that automation reduces the errors caused by manual operations and makes the processing of data possible in an acceptable amount of time.

AB - The objective of this study was to develop a method of muscle structure measurement based on the automatic analysis of muscle fibers, proximal fascias, and distal aponeurosis movements as revealed by a time-series of ultrasound images. This method was designed to detect changes in the length of muscle fiber movements, and its validity was demonstrated in a time-series of muscle movement, slow ankle dorsiflexion (10°/s), by comparison to manual measurement. The results showed that, when this method was used, the changes in the length of the muscle fiber under slow muscle movement were smaller than those in manual operations by novice individuals. However, with the proposed method, it was possible to obtain a sufficient degree of validity and reliability for the changes in the length of the muscle fiber length compared with those in manual operations, since the correlation coefficients exceeded 0.8 which was tested by the linear regression. The proposed method suggests that automation reduces the errors caused by manual operations and makes the processing of data possible in an acceptable amount of time.

KW - Automatic analysis

KW - Manual operation

KW - Muscle fiber movements

KW - Ultrasound images

UR - http://www.scopus.com/inward/record.url?scp=67349254981&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=67349254981&partnerID=8YFLogxK

U2 - 10.1016/j.medengphy.2008.11.004

DO - 10.1016/j.medengphy.2008.11.004

M3 - Article

C2 - 19110463

AN - SCOPUS:67349254981

VL - 31

SP - 558

EP - 564

JO - Medical Engineering and Physics

JF - Medical Engineering and Physics

SN - 1350-4533

IS - 5

ER -