We have developed the microfluidic chip to isolate gastric cancer cells from the peritoneal washing. Gastric cancer cells, which tend to be agglomerated in the peritoneal washing, are bigger than the other cells and the fragment of soft tissue. In this paper, we present a novel biochip to enrich low-concentrated cancer cells in the peritoneal washing by size-dependent cell filtration. This biochip has an advantage to avoid high-accuracy control of the flow rate because the cancer cells were filtered by the gap of the microchannel. Two-step exposure was carried out to achieve the precise 3D uneven channel for cell filtration. Furthermore by setting fins in the microchannel to assist the sheath flow, the capability to enrich the cancer cells was improved. As a result, we succeeded in double enrichment of the cancer cells in the quasi peritoneal washing.

Original languageEnglish
Title of host publication15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011
Pages1215-1217
Number of pages3
Volume2
Publication statusPublished - 2011
Externally publishedYes
Event15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011 - Seattle, WA
Duration: 2011 Oct 22011 Oct 6

Other

Other15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011
CitySeattle, WA
Period11/10/211/10/6

Fingerprint

Microfluidics
Cells
Washing
Biochips
Microchannels
Flow rate
Tissue

Keywords

  • Bedside
  • Cancer cell
  • Cell filtration
  • Enrichment
  • Microfluidic chip

ASJC Scopus subject areas

  • Control and Systems Engineering

Cite this

Masuda, T., Niimi, M., Nakanishi, H., Yamanishi, Y., & Arai, F. (2011). Bedside cancer cell collector using size-dependent cell filtration in microfluidic chip. In 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011 (Vol. 2, pp. 1215-1217)

Bedside cancer cell collector using size-dependent cell filtration in microfluidic chip. / Masuda, T.; Niimi, M.; Nakanishi, H.; Yamanishi, Y.; Arai, F.

15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011. Vol. 2 2011. p. 1215-1217.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Masuda, T, Niimi, M, Nakanishi, H, Yamanishi, Y & Arai, F 2011, Bedside cancer cell collector using size-dependent cell filtration in microfluidic chip. in 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011. vol. 2, pp. 1215-1217, 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011, Seattle, WA, 11/10/2.
Masuda T, Niimi M, Nakanishi H, Yamanishi Y, Arai F. Bedside cancer cell collector using size-dependent cell filtration in microfluidic chip. In 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011. Vol. 2. 2011. p. 1215-1217
Masuda, T. ; Niimi, M. ; Nakanishi, H. ; Yamanishi, Y. ; Arai, F. / Bedside cancer cell collector using size-dependent cell filtration in microfluidic chip. 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011. Vol. 2 2011. pp. 1215-1217
@inproceedings{3555f9fae16f4c9b844427227d07583f,
title = "Bedside cancer cell collector using size-dependent cell filtration in microfluidic chip",
abstract = "We have developed the microfluidic chip to isolate gastric cancer cells from the peritoneal washing. Gastric cancer cells, which tend to be agglomerated in the peritoneal washing, are bigger than the other cells and the fragment of soft tissue. In this paper, we present a novel biochip to enrich low-concentrated cancer cells in the peritoneal washing by size-dependent cell filtration. This biochip has an advantage to avoid high-accuracy control of the flow rate because the cancer cells were filtered by the gap of the microchannel. Two-step exposure was carried out to achieve the precise 3D uneven channel for cell filtration. Furthermore by setting fins in the microchannel to assist the sheath flow, the capability to enrich the cancer cells was improved. As a result, we succeeded in double enrichment of the cancer cells in the quasi peritoneal washing.",
keywords = "Bedside, Cancer cell, Cell filtration, Enrichment, Microfluidic chip",
author = "T. Masuda and M. Niimi and H. Nakanishi and Y. Yamanishi and F. Arai",
year = "2011",
language = "English",
isbn = "9781618395955",
volume = "2",
pages = "1215--1217",
booktitle = "15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011",

}

TY - GEN

T1 - Bedside cancer cell collector using size-dependent cell filtration in microfluidic chip

AU - Masuda, T.

AU - Niimi, M.

AU - Nakanishi, H.

AU - Yamanishi, Y.

AU - Arai, F.

PY - 2011

Y1 - 2011

N2 - We have developed the microfluidic chip to isolate gastric cancer cells from the peritoneal washing. Gastric cancer cells, which tend to be agglomerated in the peritoneal washing, are bigger than the other cells and the fragment of soft tissue. In this paper, we present a novel biochip to enrich low-concentrated cancer cells in the peritoneal washing by size-dependent cell filtration. This biochip has an advantage to avoid high-accuracy control of the flow rate because the cancer cells were filtered by the gap of the microchannel. Two-step exposure was carried out to achieve the precise 3D uneven channel for cell filtration. Furthermore by setting fins in the microchannel to assist the sheath flow, the capability to enrich the cancer cells was improved. As a result, we succeeded in double enrichment of the cancer cells in the quasi peritoneal washing.

AB - We have developed the microfluidic chip to isolate gastric cancer cells from the peritoneal washing. Gastric cancer cells, which tend to be agglomerated in the peritoneal washing, are bigger than the other cells and the fragment of soft tissue. In this paper, we present a novel biochip to enrich low-concentrated cancer cells in the peritoneal washing by size-dependent cell filtration. This biochip has an advantage to avoid high-accuracy control of the flow rate because the cancer cells were filtered by the gap of the microchannel. Two-step exposure was carried out to achieve the precise 3D uneven channel for cell filtration. Furthermore by setting fins in the microchannel to assist the sheath flow, the capability to enrich the cancer cells was improved. As a result, we succeeded in double enrichment of the cancer cells in the quasi peritoneal washing.

KW - Bedside

KW - Cancer cell

KW - Cell filtration

KW - Enrichment

KW - Microfluidic chip

UR - http://www.scopus.com/inward/record.url?scp=84883798661&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84883798661&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84883798661

SN - 9781618395955

VL - 2

SP - 1215

EP - 1217

BT - 15th International Conference on Miniaturized Systems for Chemistry and Life Sciences 2011, MicroTAS 2011

ER -