A system for making in vivo measurements of calcium-ion concentration is proposed. It uses a glass micro injector to locally inject a calcium indicator (fluorescent dye) in target living tissue. The fluorescent dye bonds with calcium ions to produce a level of fluorescence dependent on the concentration of those ions. The micro injector also acts as a fluorescence pickup using a photo detector installed at its base. This system injects fluorescent dye in a localized area and measures fluorescence all in a short time without having to remove living tissue from the organism in question. As such, it is a very minimally invasive measurement system that provides the essential elements of in vivo measurement. In this paper, we describe the characteristics of the injection part and fluorescence-detection part making up the system. In the injection part, we clarified the characteristics of injecting fluorescent dye by an applied voltage. Calcium concentration was measured by the fluorescence response during the injection. In the fluorescence-detection part, the glass micro injector as the pickup was proved to be suitable for measuring the localized response. Then describe the construction and evaluation of a test device combining these parts, and examine the validity of this measurement system.

Original languageEnglish
Pages (from-to)7-13
Number of pages7
JournalSensors and Actuators, B: Chemical
Volume102
Issue number1
DOIs
Publication statusPublished - 2004 Sep 1
Externally publishedYes

Fingerprint

Fluorescent Dyes
calcium
Calcium
Dyes
dyes
Fluorescence
injection
fluorescence
injectors
Pickups
Ions
Tissue
Glass
glass
sensors
ion concentration
organisms
ions
Detectors
evaluation

Keywords

  • Calcium ion
  • Fluorescent dye
  • In vivo measurement
  • Micro injector

ASJC Scopus subject areas

  • Analytical Chemistry
  • Electrochemistry
  • Electrical and Electronic Engineering

Cite this

Calcium concentration measurement by local fluorescent-dye Injection. / Nagasawa, Sumito; Shimoyama, Isao.

In: Sensors and Actuators, B: Chemical, Vol. 102, No. 1, 01.09.2004, p. 7-13.

Research output: Contribution to journalArticle

@article{ea23518f369c477cbb0226733d1f8fda,
title = "Calcium concentration measurement by local fluorescent-dye Injection",
abstract = "A system for making in vivo measurements of calcium-ion concentration is proposed. It uses a glass micro injector to locally inject a calcium indicator (fluorescent dye) in target living tissue. The fluorescent dye bonds with calcium ions to produce a level of fluorescence dependent on the concentration of those ions. The micro injector also acts as a fluorescence pickup using a photo detector installed at its base. This system injects fluorescent dye in a localized area and measures fluorescence all in a short time without having to remove living tissue from the organism in question. As such, it is a very minimally invasive measurement system that provides the essential elements of in vivo measurement. In this paper, we describe the characteristics of the injection part and fluorescence-detection part making up the system. In the injection part, we clarified the characteristics of injecting fluorescent dye by an applied voltage. Calcium concentration was measured by the fluorescence response during the injection. In the fluorescence-detection part, the glass micro injector as the pickup was proved to be suitable for measuring the localized response. Then describe the construction and evaluation of a test device combining these parts, and examine the validity of this measurement system.",
keywords = "Calcium ion, Fluorescent dye, In vivo measurement, Micro injector",
author = "Sumito Nagasawa and Isao Shimoyama",
year = "2004",
month = "9",
day = "1",
doi = "10.1016/j.snb.2003.12.079",
language = "English",
volume = "102",
pages = "7--13",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "1",

}

TY - JOUR

T1 - Calcium concentration measurement by local fluorescent-dye Injection

AU - Nagasawa, Sumito

AU - Shimoyama, Isao

PY - 2004/9/1

Y1 - 2004/9/1

N2 - A system for making in vivo measurements of calcium-ion concentration is proposed. It uses a glass micro injector to locally inject a calcium indicator (fluorescent dye) in target living tissue. The fluorescent dye bonds with calcium ions to produce a level of fluorescence dependent on the concentration of those ions. The micro injector also acts as a fluorescence pickup using a photo detector installed at its base. This system injects fluorescent dye in a localized area and measures fluorescence all in a short time without having to remove living tissue from the organism in question. As such, it is a very minimally invasive measurement system that provides the essential elements of in vivo measurement. In this paper, we describe the characteristics of the injection part and fluorescence-detection part making up the system. In the injection part, we clarified the characteristics of injecting fluorescent dye by an applied voltage. Calcium concentration was measured by the fluorescence response during the injection. In the fluorescence-detection part, the glass micro injector as the pickup was proved to be suitable for measuring the localized response. Then describe the construction and evaluation of a test device combining these parts, and examine the validity of this measurement system.

AB - A system for making in vivo measurements of calcium-ion concentration is proposed. It uses a glass micro injector to locally inject a calcium indicator (fluorescent dye) in target living tissue. The fluorescent dye bonds with calcium ions to produce a level of fluorescence dependent on the concentration of those ions. The micro injector also acts as a fluorescence pickup using a photo detector installed at its base. This system injects fluorescent dye in a localized area and measures fluorescence all in a short time without having to remove living tissue from the organism in question. As such, it is a very minimally invasive measurement system that provides the essential elements of in vivo measurement. In this paper, we describe the characteristics of the injection part and fluorescence-detection part making up the system. In the injection part, we clarified the characteristics of injecting fluorescent dye by an applied voltage. Calcium concentration was measured by the fluorescence response during the injection. In the fluorescence-detection part, the glass micro injector as the pickup was proved to be suitable for measuring the localized response. Then describe the construction and evaluation of a test device combining these parts, and examine the validity of this measurement system.

KW - Calcium ion

KW - Fluorescent dye

KW - In vivo measurement

KW - Micro injector

UR - http://www.scopus.com/inward/record.url?scp=4344578152&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=4344578152&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2003.12.079

DO - 10.1016/j.snb.2003.12.079

M3 - Article

AN - SCOPUS:4344578152

VL - 102

SP - 7

EP - 13

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 1

ER -