Abstract
A cationic surfactant- selective electrode for sensitive analysis of cationic surfactants has been developed by using a plasticized poly (vinyl chloride) membrane based on a hydrophobic cation exchanger, sodium tetrakis (3,5-bis(trifluoromethyl)phenyl) borate. The electrode shows a Nernstian response to dodecyltrimethylammonium (DTA) ion in the concentration range from 8 x 10-7M to 10-2M with a slope of 55.3 ± 2.0 mV/decade. The electrode was used over a wide pH range of pH 2-12. The electrode is excellently selective for the DTA ion over inorganic anions, but interferences of other cationic surfactants such as cetylpyridinium ion and tetradecyldimethylbenzylammonium ion (zephiramine) are great. The present electrode was applied to determine total cationic surfactants in commercial disinfectants.
Original language | English |
---|---|
Pages (from-to) | 227-231 |
Number of pages | 5 |
Journal | Mikrochimica Acta |
Volume | 140 |
Issue number | 3-4 |
DOIs | |
Publication status | Published - 2002 |
Externally published | Yes |
Fingerprint
Keywords
- Cationexchanger
- Cationic surfactant-selective electrode
- Determination of the disinfectants
- Dodecyltrimethylammonium ion
- Sodium tetrakis (3,5-bis(trifluoromethyl)phenyl) borate
- Zephiramine
ASJC Scopus subject areas
- Analytical Chemistry
Cite this
Cationic surfactant-selective electrode based on a hydrophobic cation exchanger. / Masadome, Takashi.
In: Mikrochimica Acta, Vol. 140, No. 3-4, 2002, p. 227-231.Research output: Contribution to journal › Article
}
TY - JOUR
T1 - Cationic surfactant-selective electrode based on a hydrophobic cation exchanger
AU - Masadome, Takashi
PY - 2002
Y1 - 2002
N2 - A cationic surfactant- selective electrode for sensitive analysis of cationic surfactants has been developed by using a plasticized poly (vinyl chloride) membrane based on a hydrophobic cation exchanger, sodium tetrakis (3,5-bis(trifluoromethyl)phenyl) borate. The electrode shows a Nernstian response to dodecyltrimethylammonium (DTA) ion in the concentration range from 8 x 10-7M to 10-2M with a slope of 55.3 ± 2.0 mV/decade. The electrode was used over a wide pH range of pH 2-12. The electrode is excellently selective for the DTA ion over inorganic anions, but interferences of other cationic surfactants such as cetylpyridinium ion and tetradecyldimethylbenzylammonium ion (zephiramine) are great. The present electrode was applied to determine total cationic surfactants in commercial disinfectants.
AB - A cationic surfactant- selective electrode for sensitive analysis of cationic surfactants has been developed by using a plasticized poly (vinyl chloride) membrane based on a hydrophobic cation exchanger, sodium tetrakis (3,5-bis(trifluoromethyl)phenyl) borate. The electrode shows a Nernstian response to dodecyltrimethylammonium (DTA) ion in the concentration range from 8 x 10-7M to 10-2M with a slope of 55.3 ± 2.0 mV/decade. The electrode was used over a wide pH range of pH 2-12. The electrode is excellently selective for the DTA ion over inorganic anions, but interferences of other cationic surfactants such as cetylpyridinium ion and tetradecyldimethylbenzylammonium ion (zephiramine) are great. The present electrode was applied to determine total cationic surfactants in commercial disinfectants.
KW - Cationexchanger
KW - Cationic surfactant-selective electrode
KW - Determination of the disinfectants
KW - Dodecyltrimethylammonium ion
KW - Sodium tetrakis (3,5-bis(trifluoromethyl)phenyl) borate
KW - Zephiramine
UR - http://www.scopus.com/inward/record.url?scp=0036449739&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0036449739&partnerID=8YFLogxK
U2 - 10.1007/s00604-002-0916-6
DO - 10.1007/s00604-002-0916-6
M3 - Article
AN - SCOPUS:0036449739
VL - 140
SP - 227
EP - 231
JO - Microchimica Acta
JF - Microchimica Acta
SN - 0026-3672
IS - 3-4
ER -