Cuffless blood pressure (BP) measurement is an all-inclusive term for a method that aims to measure BP without using a cuff. In our previous article, we reported the development of a simple cuffless technique based on the haemodynamic expression, using only pulse rate (PR) and modified normalized pulse volume (mNPV) that can be measured using only a smartphone. The stressor used in our previous article was the cardiac-dominant pattern (mental arithmetic); however, here we have experimented with another stressor, namely, a vascular-dominant pattern in a cold pressor test, to verify this theory in 7 healthy young males and 6 healthy young females (N = 22). As a result, the mean arterial pressure accuracy was improved (r = 0.727) compared with that achieved in the previous study.

Original languageEnglish
Title of host publication15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019
EditorsJorge Henriques, Paulo de Carvalho, Nuno Neves
PublisherSpringer
Pages874-877
Number of pages4
ISBN (Print)9783030316341
DOIs
Publication statusPublished - 2020 Jan 1
Event15th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2019 - Coimbra, Portugal
Duration: 2019 Sep 262019 Sep 28

Publication series

NameIFMBE Proceedings
Volume76
ISSN (Print)1680-0737
ISSN (Electronic)1433-9277

Conference

Conference15th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2019
CountryPortugal
CityCoimbra
Period19/9/2619/9/28

Keywords

  • Circulatory equation
  • Cuffless blood pressure
  • Heamodynamic

ASJC Scopus subject areas

  • Bioengineering
  • Biomedical Engineering

Fingerprint Dive into the research topics of 'Cuffless Blood Pressure Estimation Only an iPhone: Investigation on Cold Pressor Tests'. Together they form a unique fingerprint.

  • Cite this

    Harada, I., Mochizuki, N., Rolfe, P., Shibata, M., & Yamakoshi, T. (2020). Cuffless Blood Pressure Estimation Only an iPhone: Investigation on Cold Pressor Tests. In J. Henriques, P. de Carvalho, & N. Neves (Eds.), 15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019 (pp. 874-877). (IFMBE Proceedings; Vol. 76). Springer. https://doi.org/10.1007/978-3-030-31635-8_105