Development of a walking assistance apparatus without fixation on legs and study on the assistance effectiveness with electromyography

Eiichirou Tanaka, Tadaaki Ikehara, Yusuke Sato, Hirokazu Yusa, Kazuhisa Ito, Shozo Saegusa, Kei Nakagawa, Yoriyuki Aokage, Louis Yuge

Research output: Contribution to journalArticle

3 Citations (Scopus)

Abstract

Walking assistance is necessary for elderly and persons who engage a heavy activity. In order to meet the social requests, a walking assistance apparatus used a spatial parallel link mecharnsm have been newly developed in this research. Without making special constraints on person's legs the proposed apparatus can assist whole legs of a person including soles. To utilize the apparatus for elderly in their life, it has to output the angle velocity same as the data of able bodied person. And the equipped person has to be able to walk in various environments (inclined road and stairs, and so on) at will. Therefore the apparatus was equipped an inclination sensor and an ultrasonic sensor, then the angle of the slope and the size of stairs are measured to generate the control signal. The apparatus was equipped a control unit and lithium-ion batteries, and could drive over one hour period. To stabilize the equipped parson's posture for horizontal direction, leaf springs were attached to prevent over-adduction of hip joint. To examine the effectiveness of the proposed apparatus, the muscle fatigue while walking with wearing the apparatus was evaluated for one hour by mean power frequency (MPF) of the measured data of electromyography. As a result, the IVIPF wearing the apparatus was on maintenance tendency, while the MPF without wearing the apparatus was shifted from high-frequency range to low-frequency range. Moreover, the muscle activity in walking up the stairs was evaluated by IEMG Therefore, the effectiveness of the apparatus could be confirmed.

Original languageEnglish
Pages (from-to)1119-1132
Number of pages14
JournalNihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C
Volume77
Issue number775
Publication statusPublished - 2011
Externally publishedYes

Fingerprint

Electromyography
Stairs
Muscle
Leaf springs
Ultrasonic sensors
Fatigue of materials
Sensors

Keywords

  • Legged Locomotion
  • Mechanism
  • Medical and Welfare Assistance
  • Walking and Gait
  • Welfare Engineering

ASJC Scopus subject areas

  • Mechanical Engineering
  • Mechanics of Materials
  • Industrial and Manufacturing Engineering

Cite this

Development of a walking assistance apparatus without fixation on legs and study on the assistance effectiveness with electromyography. / Tanaka, Eiichirou; Ikehara, Tadaaki; Sato, Yusuke; Yusa, Hirokazu; Ito, Kazuhisa; Saegusa, Shozo; Nakagawa, Kei; Aokage, Yoriyuki; Yuge, Louis.

In: Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C, Vol. 77, No. 775, 2011, p. 1119-1132.

Research output: Contribution to journalArticle

Tanaka, Eiichirou ; Ikehara, Tadaaki ; Sato, Yusuke ; Yusa, Hirokazu ; Ito, Kazuhisa ; Saegusa, Shozo ; Nakagawa, Kei ; Aokage, Yoriyuki ; Yuge, Louis. / Development of a walking assistance apparatus without fixation on legs and study on the assistance effectiveness with electromyography. In: Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C. 2011 ; Vol. 77, No. 775. pp. 1119-1132.
@article{905d9f35cda5432caa47789083888426,
title = "Development of a walking assistance apparatus without fixation on legs and study on the assistance effectiveness with electromyography",
abstract = "Walking assistance is necessary for elderly and persons who engage a heavy activity. In order to meet the social requests, a walking assistance apparatus used a spatial parallel link mecharnsm have been newly developed in this research. Without making special constraints on person's legs the proposed apparatus can assist whole legs of a person including soles. To utilize the apparatus for elderly in their life, it has to output the angle velocity same as the data of able bodied person. And the equipped person has to be able to walk in various environments (inclined road and stairs, and so on) at will. Therefore the apparatus was equipped an inclination sensor and an ultrasonic sensor, then the angle of the slope and the size of stairs are measured to generate the control signal. The apparatus was equipped a control unit and lithium-ion batteries, and could drive over one hour period. To stabilize the equipped parson's posture for horizontal direction, leaf springs were attached to prevent over-adduction of hip joint. To examine the effectiveness of the proposed apparatus, the muscle fatigue while walking with wearing the apparatus was evaluated for one hour by mean power frequency (MPF) of the measured data of electromyography. As a result, the IVIPF wearing the apparatus was on maintenance tendency, while the MPF without wearing the apparatus was shifted from high-frequency range to low-frequency range. Moreover, the muscle activity in walking up the stairs was evaluated by IEMG Therefore, the effectiveness of the apparatus could be confirmed.",
keywords = "Legged Locomotion, Mechanism, Medical and Welfare Assistance, Walking and Gait, Welfare Engineering",
author = "Eiichirou Tanaka and Tadaaki Ikehara and Yusuke Sato and Hirokazu Yusa and Kazuhisa Ito and Shozo Saegusa and Kei Nakagawa and Yoriyuki Aokage and Louis Yuge",
year = "2011",
language = "English",
volume = "77",
pages = "1119--1132",
journal = "Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C",
issn = "0387-5024",
publisher = "Japan Society of Mechanical Engineers",
number = "775",

}

TY - JOUR

T1 - Development of a walking assistance apparatus without fixation on legs and study on the assistance effectiveness with electromyography

AU - Tanaka, Eiichirou

AU - Ikehara, Tadaaki

AU - Sato, Yusuke

AU - Yusa, Hirokazu

AU - Ito, Kazuhisa

AU - Saegusa, Shozo

AU - Nakagawa, Kei

AU - Aokage, Yoriyuki

AU - Yuge, Louis

PY - 2011

Y1 - 2011

N2 - Walking assistance is necessary for elderly and persons who engage a heavy activity. In order to meet the social requests, a walking assistance apparatus used a spatial parallel link mecharnsm have been newly developed in this research. Without making special constraints on person's legs the proposed apparatus can assist whole legs of a person including soles. To utilize the apparatus for elderly in their life, it has to output the angle velocity same as the data of able bodied person. And the equipped person has to be able to walk in various environments (inclined road and stairs, and so on) at will. Therefore the apparatus was equipped an inclination sensor and an ultrasonic sensor, then the angle of the slope and the size of stairs are measured to generate the control signal. The apparatus was equipped a control unit and lithium-ion batteries, and could drive over one hour period. To stabilize the equipped parson's posture for horizontal direction, leaf springs were attached to prevent over-adduction of hip joint. To examine the effectiveness of the proposed apparatus, the muscle fatigue while walking with wearing the apparatus was evaluated for one hour by mean power frequency (MPF) of the measured data of electromyography. As a result, the IVIPF wearing the apparatus was on maintenance tendency, while the MPF without wearing the apparatus was shifted from high-frequency range to low-frequency range. Moreover, the muscle activity in walking up the stairs was evaluated by IEMG Therefore, the effectiveness of the apparatus could be confirmed.

AB - Walking assistance is necessary for elderly and persons who engage a heavy activity. In order to meet the social requests, a walking assistance apparatus used a spatial parallel link mecharnsm have been newly developed in this research. Without making special constraints on person's legs the proposed apparatus can assist whole legs of a person including soles. To utilize the apparatus for elderly in their life, it has to output the angle velocity same as the data of able bodied person. And the equipped person has to be able to walk in various environments (inclined road and stairs, and so on) at will. Therefore the apparatus was equipped an inclination sensor and an ultrasonic sensor, then the angle of the slope and the size of stairs are measured to generate the control signal. The apparatus was equipped a control unit and lithium-ion batteries, and could drive over one hour period. To stabilize the equipped parson's posture for horizontal direction, leaf springs were attached to prevent over-adduction of hip joint. To examine the effectiveness of the proposed apparatus, the muscle fatigue while walking with wearing the apparatus was evaluated for one hour by mean power frequency (MPF) of the measured data of electromyography. As a result, the IVIPF wearing the apparatus was on maintenance tendency, while the MPF without wearing the apparatus was shifted from high-frequency range to low-frequency range. Moreover, the muscle activity in walking up the stairs was evaluated by IEMG Therefore, the effectiveness of the apparatus could be confirmed.

KW - Legged Locomotion

KW - Mechanism

KW - Medical and Welfare Assistance

KW - Walking and Gait

KW - Welfare Engineering

UR - http://www.scopus.com/inward/record.url?scp=84856415929&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84856415929&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:84856415929

VL - 77

SP - 1119

EP - 1132

JO - Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C

JF - Nihon Kikai Gakkai Ronbunshu, C Hen/Transactions of the Japan Society of Mechanical Engineers, Part C

SN - 0387-5024

IS - 775

ER -