Development of an EMG measuring system aiming to control upper limb orthosis with reduced discriminant error rate

Haruki Ishii, Akihiko Hanafusa, Tomohiko Shimizu, Kengo Ohnishi

Research output: Research - peer-reviewArticle

Abstract

An electromyographic (EMG) measuring system has been developed for controlling active upper limb orthoses for patients with Erbʼs palsy. Patients with Erbʼs palsy cannot move either their shoulders or elbows, but can move their wrists. Therefore, if they can move their shoulders and elbows by an orthosis, their activities of daily living (ADL) can be improved dramatically. To control the orthosis, EMGmeasurements of the four wrist movements of extension, flexion, ulnar deviation, and radial deviation are used. However, there is a risk of an erroneous motion, when a movement other than that intended is performed. Therefore, the discriminant error rate of the EMGmeasurement system should be reduced. Various channel configurations (eight, six, and four channels) were compared for measuring the EMG, and various machine learning techniques; namely, Euclidean distance (euc), Mahalanobis distance (mh), and a support vector machine (svm), were used to discriminate the movement. By defining a threshold voltage and degree of similarity, and by using the most preferred discrimination process, discriminant error rates decreased. Moreover, when the number of motions in training data for discrimination was increased from four to six by adding finger extension and flexion, the discriminant error rates using euc and svm also decreased. However, when the number of channels was reduced from eight to six or four, discriminant error rates increased. Overall, the svm method achieved the highest discriminant rate and lowest discriminant error rate. Finally, an online discrimination method was developed which achieved no difference in discriminant rate and output the results every 710 ms.

LanguageEnglish
Pages145-153
Number of pages9
JournalTransactions of Japanese Society for Medical and Biological Engineering
Volume54
Issue number3
DOIs
StatePublished - 2016

Fingerprint

Support vector machines
Threshold voltage
Learning systems

Keywords

  • Activities of daily living
  • EMG
  • Erbes paralysis
  • Machine learning
  • Upper limb orthosis

ASJC Scopus subject areas

  • Biomedical Engineering

Cite this

Development of an EMG measuring system aiming to control upper limb orthosis with reduced discriminant error rate. / Ishii, Haruki; Hanafusa, Akihiko; Shimizu, Tomohiko; Ohnishi, Kengo.

In: Transactions of Japanese Society for Medical and Biological Engineering, Vol. 54, No. 3, 2016, p. 145-153.

Research output: Research - peer-reviewArticle

@article{13c01de32cf34ef7a98ef6495b341de1,
title = "Development of an EMG measuring system aiming to control upper limb orthosis with reduced discriminant error rate",
abstract = "An electromyographic (EMG) measuring system has been developed for controlling active upper limb orthoses for patients with Erbʼs palsy. Patients with Erbʼs palsy cannot move either their shoulders or elbows, but can move their wrists. Therefore, if they can move their shoulders and elbows by an orthosis, their activities of daily living (ADL) can be improved dramatically. To control the orthosis, EMGmeasurements of the four wrist movements of extension, flexion, ulnar deviation, and radial deviation are used. However, there is a risk of an erroneous motion, when a movement other than that intended is performed. Therefore, the discriminant error rate of the EMGmeasurement system should be reduced. Various channel configurations (eight, six, and four channels) were compared for measuring the EMG, and various machine learning techniques; namely, Euclidean distance (euc), Mahalanobis distance (mh), and a support vector machine (svm), were used to discriminate the movement. By defining a threshold voltage and degree of similarity, and by using the most preferred discrimination process, discriminant error rates decreased. Moreover, when the number of motions in training data for discrimination was increased from four to six by adding finger extension and flexion, the discriminant error rates using euc and svm also decreased. However, when the number of channels was reduced from eight to six or four, discriminant error rates increased. Overall, the svm method achieved the highest discriminant rate and lowest discriminant error rate. Finally, an online discrimination method was developed which achieved no difference in discriminant rate and output the results every 710 ms.",
keywords = "Activities of daily living, EMG, Erbes paralysis, Machine learning, Upper limb orthosis",
author = "Haruki Ishii and Akihiko Hanafusa and Tomohiko Shimizu and Kengo Ohnishi",
year = "2016",
doi = "10.11239/jsmbe.54.145",
volume = "54",
pages = "145--153",
journal = "BME = Bio medical engineering / henshu, Nihon ME Gakkai",
issn = "1347-443X",
publisher = "Nihon M E Gakkai",
number = "3",

}

TY - JOUR

T1 - Development of an EMG measuring system aiming to control upper limb orthosis with reduced discriminant error rate

AU - Ishii,Haruki

AU - Hanafusa,Akihiko

AU - Shimizu,Tomohiko

AU - Ohnishi,Kengo

PY - 2016

Y1 - 2016

N2 - An electromyographic (EMG) measuring system has been developed for controlling active upper limb orthoses for patients with Erbʼs palsy. Patients with Erbʼs palsy cannot move either their shoulders or elbows, but can move their wrists. Therefore, if they can move their shoulders and elbows by an orthosis, their activities of daily living (ADL) can be improved dramatically. To control the orthosis, EMGmeasurements of the four wrist movements of extension, flexion, ulnar deviation, and radial deviation are used. However, there is a risk of an erroneous motion, when a movement other than that intended is performed. Therefore, the discriminant error rate of the EMGmeasurement system should be reduced. Various channel configurations (eight, six, and four channels) were compared for measuring the EMG, and various machine learning techniques; namely, Euclidean distance (euc), Mahalanobis distance (mh), and a support vector machine (svm), were used to discriminate the movement. By defining a threshold voltage and degree of similarity, and by using the most preferred discrimination process, discriminant error rates decreased. Moreover, when the number of motions in training data for discrimination was increased from four to six by adding finger extension and flexion, the discriminant error rates using euc and svm also decreased. However, when the number of channels was reduced from eight to six or four, discriminant error rates increased. Overall, the svm method achieved the highest discriminant rate and lowest discriminant error rate. Finally, an online discrimination method was developed which achieved no difference in discriminant rate and output the results every 710 ms.

AB - An electromyographic (EMG) measuring system has been developed for controlling active upper limb orthoses for patients with Erbʼs palsy. Patients with Erbʼs palsy cannot move either their shoulders or elbows, but can move their wrists. Therefore, if they can move their shoulders and elbows by an orthosis, their activities of daily living (ADL) can be improved dramatically. To control the orthosis, EMGmeasurements of the four wrist movements of extension, flexion, ulnar deviation, and radial deviation are used. However, there is a risk of an erroneous motion, when a movement other than that intended is performed. Therefore, the discriminant error rate of the EMGmeasurement system should be reduced. Various channel configurations (eight, six, and four channels) were compared for measuring the EMG, and various machine learning techniques; namely, Euclidean distance (euc), Mahalanobis distance (mh), and a support vector machine (svm), were used to discriminate the movement. By defining a threshold voltage and degree of similarity, and by using the most preferred discrimination process, discriminant error rates decreased. Moreover, when the number of motions in training data for discrimination was increased from four to six by adding finger extension and flexion, the discriminant error rates using euc and svm also decreased. However, when the number of channels was reduced from eight to six or four, discriminant error rates increased. Overall, the svm method achieved the highest discriminant rate and lowest discriminant error rate. Finally, an online discrimination method was developed which achieved no difference in discriminant rate and output the results every 710 ms.

KW - Activities of daily living

KW - EMG

KW - Erbes paralysis

KW - Machine learning

KW - Upper limb orthosis

UR - http://www.scopus.com/inward/record.url?scp=85009935486&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85009935486&partnerID=8YFLogxK

U2 - 10.11239/jsmbe.54.145

DO - 10.11239/jsmbe.54.145

M3 - Article

VL - 54

SP - 145

EP - 153

JO - BME = Bio medical engineering / henshu, Nihon ME Gakkai

T2 - BME = Bio medical engineering / henshu, Nihon ME Gakkai

JF - BME = Bio medical engineering / henshu, Nihon ME Gakkai

SN - 1347-443X

IS - 3

ER -