Abstract

Background: Quantification of geometric changes of the stent graft (SG) in abdominal aortic aneurysm has been required for follow up of endovascular aneurysm repair (EVAR). The aim was to develop an image-based modeling system (V-Modeler) to investigate these changes over time. Methods and Results: V-Modeler was applied to investigate the migration of the SG. Three sets of computed tomography images were taken at 3 different times: (1) 5 days after the implantation; (2) 7 months later when the unilateral leg migrated upward; and (3) 10 months later when the limb had migrated into the common iliac aneurysm resulting in a type 1b endoleak. A spline function was used to represent the center lines of the SG to track its evolutional geometric changes in a three-dimensional manner. The characteristics of vascular geometry, as well as the SG geometry using geometric parameters such as length, curvature, torsion, angle of tangent vector (ATV), and migrated length, was evaluated. It was observed that the strong peak of the curvature in the distal area appeared, and a conversion of the torsion disappeared chronologically. Conclusions: The V-Modeler was developed, which not only can extract vascular geometry but also can identify geometric parameter, such as curvature, torsion, and ATV, to predict adverse events following EVAR.

Original languageEnglish
Pages (from-to)1534-1541
Number of pages8
JournalCirculation Journal
Volume79
Issue number7
DOIs
Publication statusPublished - 2015 Jun 9

Keywords

  • Aortic aneurysm
  • Modeling system
  • Stent graft

ASJC Scopus subject areas

  • Cardiology and Cardiovascular Medicine

Cite this

Development of an image-based modeling system to investigate evolutional geometric changes of a stent graft in an abdominal aortic aneurysm. / Kobayashi, Masaharu; Hoshina, Katsuyuki; Yamamoto, Sota; Nemoto, Youkou; Akai, Takafumi; Shigematsu, Kunihiro; Watanabe, Toshiaki; Ohshima, Marie.

In: Circulation Journal, Vol. 79, No. 7, 09.06.2015, p. 1534-1541.

Research output: Contribution to journalArticle

Kobayashi, Masaharu ; Hoshina, Katsuyuki ; Yamamoto, Sota ; Nemoto, Youkou ; Akai, Takafumi ; Shigematsu, Kunihiro ; Watanabe, Toshiaki ; Ohshima, Marie. / Development of an image-based modeling system to investigate evolutional geometric changes of a stent graft in an abdominal aortic aneurysm. In: Circulation Journal. 2015 ; Vol. 79, No. 7. pp. 1534-1541.
@article{3dae31be0f634987a43283042af27f1b,
title = "Development of an image-based modeling system to investigate evolutional geometric changes of a stent graft in an abdominal aortic aneurysm",
abstract = "Background: Quantification of geometric changes of the stent graft (SG) in abdominal aortic aneurysm has been required for follow up of endovascular aneurysm repair (EVAR). The aim was to develop an image-based modeling system (V-Modeler) to investigate these changes over time. Methods and Results: V-Modeler was applied to investigate the migration of the SG. Three sets of computed tomography images were taken at 3 different times: (1) 5 days after the implantation; (2) 7 months later when the unilateral leg migrated upward; and (3) 10 months later when the limb had migrated into the common iliac aneurysm resulting in a type 1b endoleak. A spline function was used to represent the center lines of the SG to track its evolutional geometric changes in a three-dimensional manner. The characteristics of vascular geometry, as well as the SG geometry using geometric parameters such as length, curvature, torsion, angle of tangent vector (ATV), and migrated length, was evaluated. It was observed that the strong peak of the curvature in the distal area appeared, and a conversion of the torsion disappeared chronologically. Conclusions: The V-Modeler was developed, which not only can extract vascular geometry but also can identify geometric parameter, such as curvature, torsion, and ATV, to predict adverse events following EVAR.",
keywords = "Aortic aneurysm, Modeling system, Stent graft",
author = "Masaharu Kobayashi and Katsuyuki Hoshina and Sota Yamamoto and Youkou Nemoto and Takafumi Akai and Kunihiro Shigematsu and Toshiaki Watanabe and Marie Ohshima",
year = "2015",
month = "6",
day = "9",
doi = "10.1253/circj.CJ-15-0037",
language = "English",
volume = "79",
pages = "1534--1541",
journal = "Circulation Journal",
issn = "1346-9843",
publisher = "Japanese Circulation Society",
number = "7",

}

TY - JOUR

T1 - Development of an image-based modeling system to investigate evolutional geometric changes of a stent graft in an abdominal aortic aneurysm

AU - Kobayashi, Masaharu

AU - Hoshina, Katsuyuki

AU - Yamamoto, Sota

AU - Nemoto, Youkou

AU - Akai, Takafumi

AU - Shigematsu, Kunihiro

AU - Watanabe, Toshiaki

AU - Ohshima, Marie

PY - 2015/6/9

Y1 - 2015/6/9

N2 - Background: Quantification of geometric changes of the stent graft (SG) in abdominal aortic aneurysm has been required for follow up of endovascular aneurysm repair (EVAR). The aim was to develop an image-based modeling system (V-Modeler) to investigate these changes over time. Methods and Results: V-Modeler was applied to investigate the migration of the SG. Three sets of computed tomography images were taken at 3 different times: (1) 5 days after the implantation; (2) 7 months later when the unilateral leg migrated upward; and (3) 10 months later when the limb had migrated into the common iliac aneurysm resulting in a type 1b endoleak. A spline function was used to represent the center lines of the SG to track its evolutional geometric changes in a three-dimensional manner. The characteristics of vascular geometry, as well as the SG geometry using geometric parameters such as length, curvature, torsion, angle of tangent vector (ATV), and migrated length, was evaluated. It was observed that the strong peak of the curvature in the distal area appeared, and a conversion of the torsion disappeared chronologically. Conclusions: The V-Modeler was developed, which not only can extract vascular geometry but also can identify geometric parameter, such as curvature, torsion, and ATV, to predict adverse events following EVAR.

AB - Background: Quantification of geometric changes of the stent graft (SG) in abdominal aortic aneurysm has been required for follow up of endovascular aneurysm repair (EVAR). The aim was to develop an image-based modeling system (V-Modeler) to investigate these changes over time. Methods and Results: V-Modeler was applied to investigate the migration of the SG. Three sets of computed tomography images were taken at 3 different times: (1) 5 days after the implantation; (2) 7 months later when the unilateral leg migrated upward; and (3) 10 months later when the limb had migrated into the common iliac aneurysm resulting in a type 1b endoleak. A spline function was used to represent the center lines of the SG to track its evolutional geometric changes in a three-dimensional manner. The characteristics of vascular geometry, as well as the SG geometry using geometric parameters such as length, curvature, torsion, angle of tangent vector (ATV), and migrated length, was evaluated. It was observed that the strong peak of the curvature in the distal area appeared, and a conversion of the torsion disappeared chronologically. Conclusions: The V-Modeler was developed, which not only can extract vascular geometry but also can identify geometric parameter, such as curvature, torsion, and ATV, to predict adverse events following EVAR.

KW - Aortic aneurysm

KW - Modeling system

KW - Stent graft

UR - http://www.scopus.com/inward/record.url?scp=84934324868&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84934324868&partnerID=8YFLogxK

U2 - 10.1253/circj.CJ-15-0037

DO - 10.1253/circj.CJ-15-0037

M3 - Article

C2 - 25808227

AN - SCOPUS:84934324868

VL - 79

SP - 1534

EP - 1541

JO - Circulation Journal

JF - Circulation Journal

SN - 1346-9843

IS - 7

ER -