Experimental study on floor-supply displacement ventilation system under various heat load conditions

Junta Nakano, Takashi Akimoto, Shin Ichi Tanabe, Ken Ichi Kimura

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

The thermal performance of a floor-supply displacement ventilation system was evaluated in a large climate chamber designed to simulate a single span of an office building. Detailed measurements were made to investigate the indoor environment and thermal characteristics of this system. The temperature gradient in the room could be kept smaller by the cooling effect of an air-permeable floor. Lowering the height of heat sources, increasing the heat load, and decreasing the supply air volume all caused greater vertical temperature differences in the occupied zone. The temperature gradient was kept nearly constant throughout the room, though a temperature rise of 0.3°C - 0.5°C (0.5°F - 0.9°F) was observed near the heat source when clustered at one location. Perimeter load caused by warm or cold windows resulted in a disorder of the thermal stratification. Thermal comfort in the perimeter zone was considerably influenced by the radiation from the window.

Original languageEnglish
Title of host publicationIAQ Conference
Pages151-159
Number of pages9
Publication statusPublished - 1997
Externally publishedYes
EventConference on Design, Construction, and Operation of Healthy Buildings: Solutions to Global and Regional Concerns, IAQ 1997 - Washington, DC, United States
Duration: 2007 Sep 12007 Sep 1

Other

OtherConference on Design, Construction, and Operation of Healthy Buildings: Solutions to Global and Regional Concerns, IAQ 1997
CountryUnited States
CityWashington, DC
Period07/9/107/9/1

Fingerprint

Thermal load
Ventilation
Thermal gradients
Thermal stratification
Thermal comfort
Office buildings
Air
Cooling
Radiation
Temperature
Hot Temperature

ASJC Scopus subject areas

  • Building and Construction
  • Environmental Engineering
  • Public Health, Environmental and Occupational Health

Cite this

Nakano, J., Akimoto, T., Tanabe, S. I., & Kimura, K. I. (1997). Experimental study on floor-supply displacement ventilation system under various heat load conditions. In IAQ Conference (pp. 151-159)

Experimental study on floor-supply displacement ventilation system under various heat load conditions. / Nakano, Junta; Akimoto, Takashi; Tanabe, Shin Ichi; Kimura, Ken Ichi.

IAQ Conference. 1997. p. 151-159.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Nakano, J, Akimoto, T, Tanabe, SI & Kimura, KI 1997, Experimental study on floor-supply displacement ventilation system under various heat load conditions. in IAQ Conference. pp. 151-159, Conference on Design, Construction, and Operation of Healthy Buildings: Solutions to Global and Regional Concerns, IAQ 1997, Washington, DC, United States, 07/9/1.
Nakano, Junta ; Akimoto, Takashi ; Tanabe, Shin Ichi ; Kimura, Ken Ichi. / Experimental study on floor-supply displacement ventilation system under various heat load conditions. IAQ Conference. 1997. pp. 151-159
@inproceedings{c8fb888998eb4fabb5b1c8cd7a41c584,
title = "Experimental study on floor-supply displacement ventilation system under various heat load conditions",
abstract = "The thermal performance of a floor-supply displacement ventilation system was evaluated in a large climate chamber designed to simulate a single span of an office building. Detailed measurements were made to investigate the indoor environment and thermal characteristics of this system. The temperature gradient in the room could be kept smaller by the cooling effect of an air-permeable floor. Lowering the height of heat sources, increasing the heat load, and decreasing the supply air volume all caused greater vertical temperature differences in the occupied zone. The temperature gradient was kept nearly constant throughout the room, though a temperature rise of 0.3°C - 0.5°C (0.5°F - 0.9°F) was observed near the heat source when clustered at one location. Perimeter load caused by warm or cold windows resulted in a disorder of the thermal stratification. Thermal comfort in the perimeter zone was considerably influenced by the radiation from the window.",
author = "Junta Nakano and Takashi Akimoto and Tanabe, {Shin Ichi} and Kimura, {Ken Ichi}",
year = "1997",
language = "English",
pages = "151--159",
booktitle = "IAQ Conference",

}

TY - GEN

T1 - Experimental study on floor-supply displacement ventilation system under various heat load conditions

AU - Nakano, Junta

AU - Akimoto, Takashi

AU - Tanabe, Shin Ichi

AU - Kimura, Ken Ichi

PY - 1997

Y1 - 1997

N2 - The thermal performance of a floor-supply displacement ventilation system was evaluated in a large climate chamber designed to simulate a single span of an office building. Detailed measurements were made to investigate the indoor environment and thermal characteristics of this system. The temperature gradient in the room could be kept smaller by the cooling effect of an air-permeable floor. Lowering the height of heat sources, increasing the heat load, and decreasing the supply air volume all caused greater vertical temperature differences in the occupied zone. The temperature gradient was kept nearly constant throughout the room, though a temperature rise of 0.3°C - 0.5°C (0.5°F - 0.9°F) was observed near the heat source when clustered at one location. Perimeter load caused by warm or cold windows resulted in a disorder of the thermal stratification. Thermal comfort in the perimeter zone was considerably influenced by the radiation from the window.

AB - The thermal performance of a floor-supply displacement ventilation system was evaluated in a large climate chamber designed to simulate a single span of an office building. Detailed measurements were made to investigate the indoor environment and thermal characteristics of this system. The temperature gradient in the room could be kept smaller by the cooling effect of an air-permeable floor. Lowering the height of heat sources, increasing the heat load, and decreasing the supply air volume all caused greater vertical temperature differences in the occupied zone. The temperature gradient was kept nearly constant throughout the room, though a temperature rise of 0.3°C - 0.5°C (0.5°F - 0.9°F) was observed near the heat source when clustered at one location. Perimeter load caused by warm or cold windows resulted in a disorder of the thermal stratification. Thermal comfort in the perimeter zone was considerably influenced by the radiation from the window.

UR - http://www.scopus.com/inward/record.url?scp=84874255239&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84874255239&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:84874255239

SP - 151

EP - 159

BT - IAQ Conference

ER -