Gentle handling of strawberries using a suction device

Shigehiko Hayashi, Kohei Takahashi, Satoshi Yamamoto, Sadafumi Saito, Takashi Komeda

Research output: Contribution to journalArticle

15 Citations (Scopus)

Abstract

This study investigated the feasibility of gentle handling strawberries using a suction device. This picking-up method, in which the fruit itself is moved towards the suction device by a suctioning airflow, is proposed to prevent damage to the pericarp. The picking-up equipment comprises a Cartesian coordinate manipulator, suction device, machine vision system, belt conveyor, and control unit. The suction device has a tapered tube with an inner diameter of 25 mm, and generates a suction airflow of approximately 45 l min-1. The machine vision system assesses the orientation of the fruit, and the suction device approaches the fruit along the line of fruit orientation. An investigation of the effective space for suctioning revealed that the smaller the fruit, the larger the effective space. Its height was about equal to or slightly greater than half the fruit diameter; however, the permissible distance in the transverse direction was small. Because the inclination of the suctioned fruit varied considerably, our proposed picking-up method was not always able to hold the fruit in a constant posture. In the approach position (80° from the vertical), the suction device required a suction force more than double that required in the vertical position. In picking-up performance tests, success rates for four cultivars were more than 95% without dropping the fruit at an approach height of 16 mm; however, the rate decreased to 71.9% for the long-tapered 'Deco rouge' at a height of 19 mm. The time required to pick and transfer a fruit was 8.9 s.

Original languageEnglish
Pages (from-to)348-356
Number of pages9
JournalBiosystems Engineering
Volume109
Issue number4
DOIs
Publication statusPublished - 2011 Aug

Fingerprint

Fruits
suction
strawberries
fruit
fruits
computer vision
air flow
Computer vision
airflow
pericarp
posture
small fruits
Manipulators
cultivar

ASJC Scopus subject areas

  • Agronomy and Crop Science
  • Food Science
  • Animal Science and Zoology
  • Soil Science
  • Control and Systems Engineering

Cite this

Hayashi, S., Takahashi, K., Yamamoto, S., Saito, S., & Komeda, T. (2011). Gentle handling of strawberries using a suction device. Biosystems Engineering, 109(4), 348-356. https://doi.org/10.1016/j.biosystemseng.2011.04.014

Gentle handling of strawberries using a suction device. / Hayashi, Shigehiko; Takahashi, Kohei; Yamamoto, Satoshi; Saito, Sadafumi; Komeda, Takashi.

In: Biosystems Engineering, Vol. 109, No. 4, 08.2011, p. 348-356.

Research output: Contribution to journalArticle

Hayashi, S, Takahashi, K, Yamamoto, S, Saito, S & Komeda, T 2011, 'Gentle handling of strawberries using a suction device', Biosystems Engineering, vol. 109, no. 4, pp. 348-356. https://doi.org/10.1016/j.biosystemseng.2011.04.014
Hayashi, Shigehiko ; Takahashi, Kohei ; Yamamoto, Satoshi ; Saito, Sadafumi ; Komeda, Takashi. / Gentle handling of strawberries using a suction device. In: Biosystems Engineering. 2011 ; Vol. 109, No. 4. pp. 348-356.
@article{afd4732933e74eca8430f50f72831689,
title = "Gentle handling of strawberries using a suction device",
abstract = "This study investigated the feasibility of gentle handling strawberries using a suction device. This picking-up method, in which the fruit itself is moved towards the suction device by a suctioning airflow, is proposed to prevent damage to the pericarp. The picking-up equipment comprises a Cartesian coordinate manipulator, suction device, machine vision system, belt conveyor, and control unit. The suction device has a tapered tube with an inner diameter of 25 mm, and generates a suction airflow of approximately 45 l min-1. The machine vision system assesses the orientation of the fruit, and the suction device approaches the fruit along the line of fruit orientation. An investigation of the effective space for suctioning revealed that the smaller the fruit, the larger the effective space. Its height was about equal to or slightly greater than half the fruit diameter; however, the permissible distance in the transverse direction was small. Because the inclination of the suctioned fruit varied considerably, our proposed picking-up method was not always able to hold the fruit in a constant posture. In the approach position (80° from the vertical), the suction device required a suction force more than double that required in the vertical position. In picking-up performance tests, success rates for four cultivars were more than 95{\%} without dropping the fruit at an approach height of 16 mm; however, the rate decreased to 71.9{\%} for the long-tapered 'Deco rouge' at a height of 19 mm. The time required to pick and transfer a fruit was 8.9 s.",
author = "Shigehiko Hayashi and Kohei Takahashi and Satoshi Yamamoto and Sadafumi Saito and Takashi Komeda",
year = "2011",
month = "8",
doi = "10.1016/j.biosystemseng.2011.04.014",
language = "English",
volume = "109",
pages = "348--356",
journal = "Biosystems Engineering",
issn = "1537-5110",
publisher = "Academic Press Inc.",
number = "4",

}

TY - JOUR

T1 - Gentle handling of strawberries using a suction device

AU - Hayashi, Shigehiko

AU - Takahashi, Kohei

AU - Yamamoto, Satoshi

AU - Saito, Sadafumi

AU - Komeda, Takashi

PY - 2011/8

Y1 - 2011/8

N2 - This study investigated the feasibility of gentle handling strawberries using a suction device. This picking-up method, in which the fruit itself is moved towards the suction device by a suctioning airflow, is proposed to prevent damage to the pericarp. The picking-up equipment comprises a Cartesian coordinate manipulator, suction device, machine vision system, belt conveyor, and control unit. The suction device has a tapered tube with an inner diameter of 25 mm, and generates a suction airflow of approximately 45 l min-1. The machine vision system assesses the orientation of the fruit, and the suction device approaches the fruit along the line of fruit orientation. An investigation of the effective space for suctioning revealed that the smaller the fruit, the larger the effective space. Its height was about equal to or slightly greater than half the fruit diameter; however, the permissible distance in the transverse direction was small. Because the inclination of the suctioned fruit varied considerably, our proposed picking-up method was not always able to hold the fruit in a constant posture. In the approach position (80° from the vertical), the suction device required a suction force more than double that required in the vertical position. In picking-up performance tests, success rates for four cultivars were more than 95% without dropping the fruit at an approach height of 16 mm; however, the rate decreased to 71.9% for the long-tapered 'Deco rouge' at a height of 19 mm. The time required to pick and transfer a fruit was 8.9 s.

AB - This study investigated the feasibility of gentle handling strawberries using a suction device. This picking-up method, in which the fruit itself is moved towards the suction device by a suctioning airflow, is proposed to prevent damage to the pericarp. The picking-up equipment comprises a Cartesian coordinate manipulator, suction device, machine vision system, belt conveyor, and control unit. The suction device has a tapered tube with an inner diameter of 25 mm, and generates a suction airflow of approximately 45 l min-1. The machine vision system assesses the orientation of the fruit, and the suction device approaches the fruit along the line of fruit orientation. An investigation of the effective space for suctioning revealed that the smaller the fruit, the larger the effective space. Its height was about equal to or slightly greater than half the fruit diameter; however, the permissible distance in the transverse direction was small. Because the inclination of the suctioned fruit varied considerably, our proposed picking-up method was not always able to hold the fruit in a constant posture. In the approach position (80° from the vertical), the suction device required a suction force more than double that required in the vertical position. In picking-up performance tests, success rates for four cultivars were more than 95% without dropping the fruit at an approach height of 16 mm; however, the rate decreased to 71.9% for the long-tapered 'Deco rouge' at a height of 19 mm. The time required to pick and transfer a fruit was 8.9 s.

UR - http://www.scopus.com/inward/record.url?scp=79960246598&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79960246598&partnerID=8YFLogxK

U2 - 10.1016/j.biosystemseng.2011.04.014

DO - 10.1016/j.biosystemseng.2011.04.014

M3 - Article

VL - 109

SP - 348

EP - 356

JO - Biosystems Engineering

JF - Biosystems Engineering

SN - 1537-5110

IS - 4

ER -