Abstract
This paper investigates the quality of RC structure which has passed since completion for 75 years at the time of the demolition work of the first RC housing in Osaka constructed in the period of Showa five to six years. As a result, the following knowledge was acquired. (1) Values with sufficient compressive strength of core-analysis specimens were secured. (2) The carbonation depth of concrete was about 37mm in the outdoor side and about 45mm in the interior room side. (3) Cover thickness of steel bars was a value almost equivalent to the present standard point.
Original language | English |
---|---|
Pages (from-to) | 367-371 |
Number of pages | 5 |
Journal | AIJ Journal of Technology and Design |
Volume | 15 |
Issue number | 30 |
DOIs | |
Publication status | Published - 2009 Jun |
Externally published | Yes |
Keywords
- Carbonation
- Compressive strength
- Corrosion
- RC Housing
ASJC Scopus subject areas
- Architecture
- Building and Construction