Seismic performance and flexural stiffness variation of assembled precast high-strength concrete beam jointed at mid-span using transverse bolts

Hassane Ousalem, Yuji Ishikawa, Hideki Kimura, Tetsu Kusaka, Nobuyuki Yanagisawa, Keijiro Okamoto

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

Assembled precast members and related connections should be economically feasible, bring ease of construction, and provide acceptable static properties as well as adequate dynamic characteristics in high seismic zones. The seismic performance of an assembled precast high-strength concrete beam with a simple and innovative lap splice connection in high-rise buildings is discussed. The flexibility variation along the lap splice connection of the beam, which involves a reduced profile, is also investigated. The lap splice connection, located at beam mid-span, was connected by transverse untensioned bolts. The simplicity of the form and developed mechanism are intended to be suitable for construction sites. The experimental test results confirmed the adequacy of such assemblies to satisfy a safe level under different loadings. The beam under reversed cyclic loading proved to be ductile and failure occurred outside the lap splice connection similarly to monolithic ordinary reinforced concrete beams. The flexural stiffness varied along the lap splice connection of the assembled beam and declined at the transition section of the reduced profile under large loading. Therefore, this reduction, within design limits, would not affect the performance of the assembled beam.

Original languageEnglish
Pages (from-to)205-216
Number of pages12
JournalJournal of Advanced Concrete Technology
Volume7
Issue number2
DOIs
Publication statusPublished - 2009 Dec 1
Externally publishedYes

Fingerprint

Bolts
Stiffness
Concretes
Reinforced concrete

ASJC Scopus subject areas

  • Building and Construction
  • Materials Science(all)

Cite this

Seismic performance and flexural stiffness variation of assembled precast high-strength concrete beam jointed at mid-span using transverse bolts. / Ousalem, Hassane; Ishikawa, Yuji; Kimura, Hideki; Kusaka, Tetsu; Yanagisawa, Nobuyuki; Okamoto, Keijiro.

In: Journal of Advanced Concrete Technology, Vol. 7, No. 2, 01.12.2009, p. 205-216.

Research output: Contribution to journalArticle

Ousalem, Hassane ; Ishikawa, Yuji ; Kimura, Hideki ; Kusaka, Tetsu ; Yanagisawa, Nobuyuki ; Okamoto, Keijiro. / Seismic performance and flexural stiffness variation of assembled precast high-strength concrete beam jointed at mid-span using transverse bolts. In: Journal of Advanced Concrete Technology. 2009 ; Vol. 7, No. 2. pp. 205-216.
@article{9aa6aff7ee144824b46905ef77f47cd0,
title = "Seismic performance and flexural stiffness variation of assembled precast high-strength concrete beam jointed at mid-span using transverse bolts",
abstract = "Assembled precast members and related connections should be economically feasible, bring ease of construction, and provide acceptable static properties as well as adequate dynamic characteristics in high seismic zones. The seismic performance of an assembled precast high-strength concrete beam with a simple and innovative lap splice connection in high-rise buildings is discussed. The flexibility variation along the lap splice connection of the beam, which involves a reduced profile, is also investigated. The lap splice connection, located at beam mid-span, was connected by transverse untensioned bolts. The simplicity of the form and developed mechanism are intended to be suitable for construction sites. The experimental test results confirmed the adequacy of such assemblies to satisfy a safe level under different loadings. The beam under reversed cyclic loading proved to be ductile and failure occurred outside the lap splice connection similarly to monolithic ordinary reinforced concrete beams. The flexural stiffness varied along the lap splice connection of the assembled beam and declined at the transition section of the reduced profile under large loading. Therefore, this reduction, within design limits, would not affect the performance of the assembled beam.",
author = "Hassane Ousalem and Yuji Ishikawa and Hideki Kimura and Tetsu Kusaka and Nobuyuki Yanagisawa and Keijiro Okamoto",
year = "2009",
month = "12",
day = "1",
doi = "10.3151/jact.7.205",
language = "English",
volume = "7",
pages = "205--216",
journal = "Journal of Advanced Concrete Technology",
issn = "1346-8014",
publisher = "Japan Concrete Institute",
number = "2",

}

TY - JOUR

T1 - Seismic performance and flexural stiffness variation of assembled precast high-strength concrete beam jointed at mid-span using transverse bolts

AU - Ousalem, Hassane

AU - Ishikawa, Yuji

AU - Kimura, Hideki

AU - Kusaka, Tetsu

AU - Yanagisawa, Nobuyuki

AU - Okamoto, Keijiro

PY - 2009/12/1

Y1 - 2009/12/1

N2 - Assembled precast members and related connections should be economically feasible, bring ease of construction, and provide acceptable static properties as well as adequate dynamic characteristics in high seismic zones. The seismic performance of an assembled precast high-strength concrete beam with a simple and innovative lap splice connection in high-rise buildings is discussed. The flexibility variation along the lap splice connection of the beam, which involves a reduced profile, is also investigated. The lap splice connection, located at beam mid-span, was connected by transverse untensioned bolts. The simplicity of the form and developed mechanism are intended to be suitable for construction sites. The experimental test results confirmed the adequacy of such assemblies to satisfy a safe level under different loadings. The beam under reversed cyclic loading proved to be ductile and failure occurred outside the lap splice connection similarly to monolithic ordinary reinforced concrete beams. The flexural stiffness varied along the lap splice connection of the assembled beam and declined at the transition section of the reduced profile under large loading. Therefore, this reduction, within design limits, would not affect the performance of the assembled beam.

AB - Assembled precast members and related connections should be economically feasible, bring ease of construction, and provide acceptable static properties as well as adequate dynamic characteristics in high seismic zones. The seismic performance of an assembled precast high-strength concrete beam with a simple and innovative lap splice connection in high-rise buildings is discussed. The flexibility variation along the lap splice connection of the beam, which involves a reduced profile, is also investigated. The lap splice connection, located at beam mid-span, was connected by transverse untensioned bolts. The simplicity of the form and developed mechanism are intended to be suitable for construction sites. The experimental test results confirmed the adequacy of such assemblies to satisfy a safe level under different loadings. The beam under reversed cyclic loading proved to be ductile and failure occurred outside the lap splice connection similarly to monolithic ordinary reinforced concrete beams. The flexural stiffness varied along the lap splice connection of the assembled beam and declined at the transition section of the reduced profile under large loading. Therefore, this reduction, within design limits, would not affect the performance of the assembled beam.

UR - http://www.scopus.com/inward/record.url?scp=79954466346&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=79954466346&partnerID=8YFLogxK

U2 - 10.3151/jact.7.205

DO - 10.3151/jact.7.205

M3 - Article

VL - 7

SP - 205

EP - 216

JO - Journal of Advanced Concrete Technology

JF - Journal of Advanced Concrete Technology

SN - 1346-8014

IS - 2