Sensorless control of dual-active-bridge converter with reduced-order proportional-integral observer

Duy Dinh Nguyen, Dinh Hoa Nguyen, Toshihisa Funabashi, Goro Fujita

Research output: Contribution to journalArticle

2 Citations (Scopus)

Abstract

When controlling a Dual-Active-Bridge (DAB) DC/DC converter, the high frequency terminal current is usually measured for use in the current feedback controller. In order to measure that current, a wide bandwidth sensor accompanied with high-speed amplifiers are required. Furthermore, a high Analog-to-Digital sampling rate is also necessary for sampling and processing the measured data. To avoid those expensive requirements, this paper proposes an alternative control method for the DAB converter. In the proposed method, the terminal current is estimated by a reduced-order proportional integral observer. A technique is also proposed to reduce the phase drift effect when the voltages at two terminals are not matched. Afterwards, a combined current feedforward-voltage feedback control system is developed to enhance the system dynamics and to regulate the output voltage. This control system needs only the information of the terminal voltages and no current sensor is required. Experimental results show that the observer can estimate the terminal current very quickly with the accuracy of more than 98%. In addition, the output voltage is well regulated with a fluctuation of less than 2.6% and a settling time of less than 6.5 ms in the presence of a 30% load change.

Original languageEnglish
Article numberen11040931
JournalEnergies
Volume11
Issue number4
DOIs
Publication statusPublished - 2018 Apr 1

Fingerprint

Electric potential
Sampling
Control systems
Sensors
DC-DC converters
Voltage control
Feedback control
Dynamical systems
Feedback
Bandwidth
Controllers
Sensorless control
Processing

Keywords

  • Dual-active-bridge DC/DC converter
  • Feedforward current control
  • Observer-based control system
  • Proportional integral observer
  • Reduced-order observer

ASJC Scopus subject areas

  • Renewable Energy, Sustainability and the Environment
  • Energy Engineering and Power Technology
  • Energy (miscellaneous)
  • Control and Optimization
  • Electrical and Electronic Engineering

Cite this

Sensorless control of dual-active-bridge converter with reduced-order proportional-integral observer. / Nguyen, Duy Dinh; Nguyen, Dinh Hoa; Funabashi, Toshihisa; Fujita, Goro.

In: Energies, Vol. 11, No. 4, en11040931, 01.04.2018.

Research output: Contribution to journalArticle

Nguyen, Duy Dinh ; Nguyen, Dinh Hoa ; Funabashi, Toshihisa ; Fujita, Goro. / Sensorless control of dual-active-bridge converter with reduced-order proportional-integral observer. In: Energies. 2018 ; Vol. 11, No. 4.
@article{7786b00bdb1044eebcfae975f9405216,
title = "Sensorless control of dual-active-bridge converter with reduced-order proportional-integral observer",
abstract = "When controlling a Dual-Active-Bridge (DAB) DC/DC converter, the high frequency terminal current is usually measured for use in the current feedback controller. In order to measure that current, a wide bandwidth sensor accompanied with high-speed amplifiers are required. Furthermore, a high Analog-to-Digital sampling rate is also necessary for sampling and processing the measured data. To avoid those expensive requirements, this paper proposes an alternative control method for the DAB converter. In the proposed method, the terminal current is estimated by a reduced-order proportional integral observer. A technique is also proposed to reduce the phase drift effect when the voltages at two terminals are not matched. Afterwards, a combined current feedforward-voltage feedback control system is developed to enhance the system dynamics and to regulate the output voltage. This control system needs only the information of the terminal voltages and no current sensor is required. Experimental results show that the observer can estimate the terminal current very quickly with the accuracy of more than 98{\%}. In addition, the output voltage is well regulated with a fluctuation of less than 2.6{\%} and a settling time of less than 6.5 ms in the presence of a 30{\%} load change.",
keywords = "Dual-active-bridge DC/DC converter, Feedforward current control, Observer-based control system, Proportional integral observer, Reduced-order observer",
author = "Nguyen, {Duy Dinh} and Nguyen, {Dinh Hoa} and Toshihisa Funabashi and Goro Fujita",
year = "2018",
month = "4",
day = "1",
doi = "10.3390/en11040931",
language = "English",
volume = "11",
journal = "Energies",
issn = "1996-1073",
publisher = "Multidisciplinary Digital Publishing Institute (MDPI)",
number = "4",

}

TY - JOUR

T1 - Sensorless control of dual-active-bridge converter with reduced-order proportional-integral observer

AU - Nguyen, Duy Dinh

AU - Nguyen, Dinh Hoa

AU - Funabashi, Toshihisa

AU - Fujita, Goro

PY - 2018/4/1

Y1 - 2018/4/1

N2 - When controlling a Dual-Active-Bridge (DAB) DC/DC converter, the high frequency terminal current is usually measured for use in the current feedback controller. In order to measure that current, a wide bandwidth sensor accompanied with high-speed amplifiers are required. Furthermore, a high Analog-to-Digital sampling rate is also necessary for sampling and processing the measured data. To avoid those expensive requirements, this paper proposes an alternative control method for the DAB converter. In the proposed method, the terminal current is estimated by a reduced-order proportional integral observer. A technique is also proposed to reduce the phase drift effect when the voltages at two terminals are not matched. Afterwards, a combined current feedforward-voltage feedback control system is developed to enhance the system dynamics and to regulate the output voltage. This control system needs only the information of the terminal voltages and no current sensor is required. Experimental results show that the observer can estimate the terminal current very quickly with the accuracy of more than 98%. In addition, the output voltage is well regulated with a fluctuation of less than 2.6% and a settling time of less than 6.5 ms in the presence of a 30% load change.

AB - When controlling a Dual-Active-Bridge (DAB) DC/DC converter, the high frequency terminal current is usually measured for use in the current feedback controller. In order to measure that current, a wide bandwidth sensor accompanied with high-speed amplifiers are required. Furthermore, a high Analog-to-Digital sampling rate is also necessary for sampling and processing the measured data. To avoid those expensive requirements, this paper proposes an alternative control method for the DAB converter. In the proposed method, the terminal current is estimated by a reduced-order proportional integral observer. A technique is also proposed to reduce the phase drift effect when the voltages at two terminals are not matched. Afterwards, a combined current feedforward-voltage feedback control system is developed to enhance the system dynamics and to regulate the output voltage. This control system needs only the information of the terminal voltages and no current sensor is required. Experimental results show that the observer can estimate the terminal current very quickly with the accuracy of more than 98%. In addition, the output voltage is well regulated with a fluctuation of less than 2.6% and a settling time of less than 6.5 ms in the presence of a 30% load change.

KW - Dual-active-bridge DC/DC converter

KW - Feedforward current control

KW - Observer-based control system

KW - Proportional integral observer

KW - Reduced-order observer

UR - http://www.scopus.com/inward/record.url?scp=85054035352&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85054035352&partnerID=8YFLogxK

U2 - 10.3390/en11040931

DO - 10.3390/en11040931

M3 - Article

AN - SCOPUS:85054035352

VL - 11

JO - Energies

JF - Energies

SN - 1996-1073

IS - 4

M1 - en11040931

ER -