Abstract

Automating ubiquitous surgical subtasks such as suturing makes surgery more efficient, e.g., reduction of surgeon fatigue and/or surgery time. However, fully autonomous control in a surgical robot is still difficult due to individual differences in layout and deformation of human organs. In this paper, we propose a system consisting of a single master and dual slave, in which the operator commands one of the slaves manually through a master and the other slave autonomously moves. The operator inserts the needle to organ manually using one of the slaves (Slave A1) with a master. The other slave (Slave A2) automatically grasps the tip of the needle and pulls it out from the organ, and hands the needle back to Slave A1 automatically. Finally, Slave A1 regrasps the needle and the suturing is performed by repeating this procedure. The estimated external force is used to recognize the needle insertion by Slave A1, which is manually controlled with the master. This recognition of external force is used as a trigger to start the autonomous approach of Slave A2 to grasp the needle. We conducted single throwing and reinsertion in the experiment and compared the completion time using the proposed system and conventional bimanual teleoperation. The completion time was decreased by an average of 20% in total.

Original languageEnglish
Pages (from-to)6343-6351
Number of pages9
JournalIEEE Transactions on Industrial Electronics
Volume65
Issue number8
DOIs
Publication statusPublished - 2018 Aug 1

Fingerprint

Needles
Surgery
Remote control
Robotic surgery
Fatigue of materials
Experiments

Keywords

  • Automation
  • forceps manipulator
  • pneumatic system
  • surgical robot
  • wire-driven mechanism

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Electrical and Electronic Engineering

Cite this

Single-Master Dual-Slave Surgical Robot with Automated Relay of Suture Needle. / Watanabe, Kengo; Kanno, Takahiro; Ito, Kazuhisa; Kawashima, Kenji.

In: IEEE Transactions on Industrial Electronics, Vol. 65, No. 8, 01.08.2018, p. 6343-6351.

Research output: Contribution to journalArticle

Watanabe, Kengo ; Kanno, Takahiro ; Ito, Kazuhisa ; Kawashima, Kenji. / Single-Master Dual-Slave Surgical Robot with Automated Relay of Suture Needle. In: IEEE Transactions on Industrial Electronics. 2018 ; Vol. 65, No. 8. pp. 6343-6351.
@article{41c3340da755418dbfa6986d0c6309e2,
title = "Single-Master Dual-Slave Surgical Robot with Automated Relay of Suture Needle",
abstract = "Automating ubiquitous surgical subtasks such as suturing makes surgery more efficient, e.g., reduction of surgeon fatigue and/or surgery time. However, fully autonomous control in a surgical robot is still difficult due to individual differences in layout and deformation of human organs. In this paper, we propose a system consisting of a single master and dual slave, in which the operator commands one of the slaves manually through a master and the other slave autonomously moves. The operator inserts the needle to organ manually using one of the slaves (Slave A1) with a master. The other slave (Slave A2) automatically grasps the tip of the needle and pulls it out from the organ, and hands the needle back to Slave A1 automatically. Finally, Slave A1 regrasps the needle and the suturing is performed by repeating this procedure. The estimated external force is used to recognize the needle insertion by Slave A1, which is manually controlled with the master. This recognition of external force is used as a trigger to start the autonomous approach of Slave A2 to grasp the needle. We conducted single throwing and reinsertion in the experiment and compared the completion time using the proposed system and conventional bimanual teleoperation. The completion time was decreased by an average of 20{\%} in total.",
keywords = "Automation, forceps manipulator, pneumatic system, surgical robot, wire-driven mechanism",
author = "Kengo Watanabe and Takahiro Kanno and Kazuhisa Ito and Kenji Kawashima",
year = "2018",
month = "8",
day = "1",
doi = "10.1109/TIE.2017.2786206",
language = "English",
volume = "65",
pages = "6343--6351",
journal = "IEEE Transactions on Industrial Electronics",
issn = "0278-0046",
publisher = "IEEE Industrial Electronics Society",
number = "8",

}

TY - JOUR

T1 - Single-Master Dual-Slave Surgical Robot with Automated Relay of Suture Needle

AU - Watanabe, Kengo

AU - Kanno, Takahiro

AU - Ito, Kazuhisa

AU - Kawashima, Kenji

PY - 2018/8/1

Y1 - 2018/8/1

N2 - Automating ubiquitous surgical subtasks such as suturing makes surgery more efficient, e.g., reduction of surgeon fatigue and/or surgery time. However, fully autonomous control in a surgical robot is still difficult due to individual differences in layout and deformation of human organs. In this paper, we propose a system consisting of a single master and dual slave, in which the operator commands one of the slaves manually through a master and the other slave autonomously moves. The operator inserts the needle to organ manually using one of the slaves (Slave A1) with a master. The other slave (Slave A2) automatically grasps the tip of the needle and pulls it out from the organ, and hands the needle back to Slave A1 automatically. Finally, Slave A1 regrasps the needle and the suturing is performed by repeating this procedure. The estimated external force is used to recognize the needle insertion by Slave A1, which is manually controlled with the master. This recognition of external force is used as a trigger to start the autonomous approach of Slave A2 to grasp the needle. We conducted single throwing and reinsertion in the experiment and compared the completion time using the proposed system and conventional bimanual teleoperation. The completion time was decreased by an average of 20% in total.

AB - Automating ubiquitous surgical subtasks such as suturing makes surgery more efficient, e.g., reduction of surgeon fatigue and/or surgery time. However, fully autonomous control in a surgical robot is still difficult due to individual differences in layout and deformation of human organs. In this paper, we propose a system consisting of a single master and dual slave, in which the operator commands one of the slaves manually through a master and the other slave autonomously moves. The operator inserts the needle to organ manually using one of the slaves (Slave A1) with a master. The other slave (Slave A2) automatically grasps the tip of the needle and pulls it out from the organ, and hands the needle back to Slave A1 automatically. Finally, Slave A1 regrasps the needle and the suturing is performed by repeating this procedure. The estimated external force is used to recognize the needle insertion by Slave A1, which is manually controlled with the master. This recognition of external force is used as a trigger to start the autonomous approach of Slave A2 to grasp the needle. We conducted single throwing and reinsertion in the experiment and compared the completion time using the proposed system and conventional bimanual teleoperation. The completion time was decreased by an average of 20% in total.

KW - Automation

KW - forceps manipulator

KW - pneumatic system

KW - surgical robot

KW - wire-driven mechanism

UR - http://www.scopus.com/inward/record.url?scp=85039778098&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85039778098&partnerID=8YFLogxK

U2 - 10.1109/TIE.2017.2786206

DO - 10.1109/TIE.2017.2786206

M3 - Article

AN - SCOPUS:85039778098

VL - 65

SP - 6343

EP - 6351

JO - IEEE Transactions on Industrial Electronics

JF - IEEE Transactions on Industrial Electronics

SN - 0278-0046

IS - 8

ER -