Abstract
It is very important for concrete structures to keep the compressive strength and durability. In order to demonstrate such performances, it is indispensable to curing of concrete. However these performances cannot be checked within the curing period. In this research, it is proposed the technique of predicting the strength and durability during curing period using electrical resistance. As a result, it has high correlation with the electrical resistance value at the demolding time and the compressive strength, carbonation depth.
Original language | English |
---|---|
Article number | e313 |
Journal | Sustainable Construction Materials and Technologies |
Volume | 2013-August |
Publication status | Published - 2013 Jan 1 |
Event | 3rd International Conference on Sustainable Construction Materials and Technologies, SCMT 2013 - Kyoto, Japan Duration: 2013 Aug 18 → 2013 Aug 21 |
Keywords
- Blast-Furnace slag cement
- Compressive strength at demolding time
- Curing
- Durability
- Electrical resistance
ASJC Scopus subject areas
- Civil and Structural Engineering
- Building and Construction
- Mechanics of Materials
- Materials Science(all)