The Evaluation of Air Blowing Method of Variable-Air-Conditioning-System using Coanda Effect by Computational Fluid Dynamics

H. Sakakibara, Takashi Akimoto, H. Igarashi, S. Nakamura, M. Kimura

Research output: Contribution to journalConference article

Abstract

Government of Japan aims to achieve net zero energy buildings on average regarding newly constructed buildings by 2030. Therefore, we studied the ductless air conditioning system using Coanda effect which is one of the technologies to realize net zero energy buildings. By reducing duct space on the ceiling, it can reduce fan power and save resources. However, when the amount of blowing air volume is small, there is the possibility the conditioned air is not diffuse into the room. Also, when the blowing air volume is large, the draft airflow possibly occurs. Hence, the distribution of the airflow in the room was confirmed by computational fluid dynamics. 15 cases were analysed at the thermal load of 30%, 50% and 100%. The default case was set as the blowing temperature difference of 10 Kelvin and the blowing wind speed of 3.0 meters per second. Then, Air Diffusion Performance Index was calculated from Effective Draft Temperature. As a result, the thermal comfort was generally good when the thermal load was 100%. However, there were some cases that the thermal comfort was low by the draft and hot spaces. It was comfortable in most cases when the thermal load was 30% and 50%.

Original languageEnglish
Article number012058
JournalIOP Conference Series: Earth and Environmental Science
Volume294
Issue number1
DOIs
Publication statusPublished - 2019 Aug 9
EventSustainable Built Environment Conference 2019 Tokyo: Built Environment in an Era of Climate Change: How Can Cities and Buildings Adapt?, SBE 2019 Tokyo - Tokyo, Japan
Duration: 2019 Aug 62019 Aug 7

Fingerprint

air conditioning
computational fluid dynamics
air
airflow
energy
wind velocity
temperature
evaluation
effect
method
resource

ASJC Scopus subject areas

  • Environmental Science(all)
  • Earth and Planetary Sciences(all)

Cite this

The Evaluation of Air Blowing Method of Variable-Air-Conditioning-System using Coanda Effect by Computational Fluid Dynamics. / Sakakibara, H.; Akimoto, Takashi; Igarashi, H.; Nakamura, S.; Kimura, M.

In: IOP Conference Series: Earth and Environmental Science, Vol. 294, No. 1, 012058, 09.08.2019.

Research output: Contribution to journalConference article

@article{3cfd8027d3bb42b8a913a52c7acfa595,
title = "The Evaluation of Air Blowing Method of Variable-Air-Conditioning-System using Coanda Effect by Computational Fluid Dynamics",
abstract = "Government of Japan aims to achieve net zero energy buildings on average regarding newly constructed buildings by 2030. Therefore, we studied the ductless air conditioning system using Coanda effect which is one of the technologies to realize net zero energy buildings. By reducing duct space on the ceiling, it can reduce fan power and save resources. However, when the amount of blowing air volume is small, there is the possibility the conditioned air is not diffuse into the room. Also, when the blowing air volume is large, the draft airflow possibly occurs. Hence, the distribution of the airflow in the room was confirmed by computational fluid dynamics. 15 cases were analysed at the thermal load of 30{\%}, 50{\%} and 100{\%}. The default case was set as the blowing temperature difference of 10 Kelvin and the blowing wind speed of 3.0 meters per second. Then, Air Diffusion Performance Index was calculated from Effective Draft Temperature. As a result, the thermal comfort was generally good when the thermal load was 100{\%}. However, there were some cases that the thermal comfort was low by the draft and hot spaces. It was comfortable in most cases when the thermal load was 30{\%} and 50{\%}.",
author = "H. Sakakibara and Takashi Akimoto and H. Igarashi and S. Nakamura and M. Kimura",
year = "2019",
month = "8",
day = "9",
doi = "10.1088/1755-1315/294/1/012058",
language = "English",
volume = "294",
journal = "IOP Conference Series: Earth and Environmental Science",
issn = "1755-1307",
publisher = "IOP Publishing Ltd.",
number = "1",

}

TY - JOUR

T1 - The Evaluation of Air Blowing Method of Variable-Air-Conditioning-System using Coanda Effect by Computational Fluid Dynamics

AU - Sakakibara, H.

AU - Akimoto, Takashi

AU - Igarashi, H.

AU - Nakamura, S.

AU - Kimura, M.

PY - 2019/8/9

Y1 - 2019/8/9

N2 - Government of Japan aims to achieve net zero energy buildings on average regarding newly constructed buildings by 2030. Therefore, we studied the ductless air conditioning system using Coanda effect which is one of the technologies to realize net zero energy buildings. By reducing duct space on the ceiling, it can reduce fan power and save resources. However, when the amount of blowing air volume is small, there is the possibility the conditioned air is not diffuse into the room. Also, when the blowing air volume is large, the draft airflow possibly occurs. Hence, the distribution of the airflow in the room was confirmed by computational fluid dynamics. 15 cases were analysed at the thermal load of 30%, 50% and 100%. The default case was set as the blowing temperature difference of 10 Kelvin and the blowing wind speed of 3.0 meters per second. Then, Air Diffusion Performance Index was calculated from Effective Draft Temperature. As a result, the thermal comfort was generally good when the thermal load was 100%. However, there were some cases that the thermal comfort was low by the draft and hot spaces. It was comfortable in most cases when the thermal load was 30% and 50%.

AB - Government of Japan aims to achieve net zero energy buildings on average regarding newly constructed buildings by 2030. Therefore, we studied the ductless air conditioning system using Coanda effect which is one of the technologies to realize net zero energy buildings. By reducing duct space on the ceiling, it can reduce fan power and save resources. However, when the amount of blowing air volume is small, there is the possibility the conditioned air is not diffuse into the room. Also, when the blowing air volume is large, the draft airflow possibly occurs. Hence, the distribution of the airflow in the room was confirmed by computational fluid dynamics. 15 cases were analysed at the thermal load of 30%, 50% and 100%. The default case was set as the blowing temperature difference of 10 Kelvin and the blowing wind speed of 3.0 meters per second. Then, Air Diffusion Performance Index was calculated from Effective Draft Temperature. As a result, the thermal comfort was generally good when the thermal load was 100%. However, there were some cases that the thermal comfort was low by the draft and hot spaces. It was comfortable in most cases when the thermal load was 30% and 50%.

UR - http://www.scopus.com/inward/record.url?scp=85071854448&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85071854448&partnerID=8YFLogxK

U2 - 10.1088/1755-1315/294/1/012058

DO - 10.1088/1755-1315/294/1/012058

M3 - Conference article

AN - SCOPUS:85071854448

VL - 294

JO - IOP Conference Series: Earth and Environmental Science

JF - IOP Conference Series: Earth and Environmental Science

SN - 1755-1307

IS - 1

M1 - 012058

ER -