The examination of air blowing method and thermal comfort of variable air conditioning system using coanda effect

Hikari Sakakibara, Takashi Akimoto, Hitomi Igarashi, Shunsuke Nakamura, Madoka Kimura

Research output: Contribution to journalConference article

Abstract

The "Strategic Energy Plan" implemented by the Cabinet of Japan in 2014 strives for zero energy building design for typical new construction by 2030. The present study focuses on a ductless and variable air conditioning system, using the Coanda effect, with the aim of reducing fan power, and saving of resources by reducing the space between the ceiling. In this study, we examined the air blowing method and evaluated thermal comfort using computational fluid dynamics as well as subjective perception of coolness in a midsize office. A draft zone was reduced by extending the interval between conditioned air outlets. However, if the extension of throw length was excessive, hot space would be formed near the air outlets, and there would be a risk of impacting thermal comfort. Moreover, we confirmed that the thermal comfort was generally favourable. In particular, perceived thermal comfort was better at the position in the office where the air flow landed on the upper body of the subjects. On the other hand, it decreased when the influence of the air flow was small, and at the point where air flow landed on the lower body of the subjects.

Original languageEnglish
Article number01079
JournalE3S Web of Conferences
Volume111
DOIs
Publication statusPublished - 2019 Aug 13
Event13th REHVA World Congress, CLIMA 2019 - Bucharest, Romania
Duration: 2019 May 262019 May 29

Fingerprint

Thermal comfort
air conditioning
Blow molding
Air conditioning
airflow
air
Air
architectural design
computational fluid dynamics
energy
Ceilings
resource
Fans
effect
method
Computational fluid dynamics
office

ASJC Scopus subject areas

  • Environmental Science(all)
  • Energy(all)
  • Earth and Planetary Sciences(all)

Cite this

The examination of air blowing method and thermal comfort of variable air conditioning system using coanda effect. / Sakakibara, Hikari; Akimoto, Takashi; Igarashi, Hitomi; Nakamura, Shunsuke; Kimura, Madoka.

In: E3S Web of Conferences, Vol. 111, 01079, 13.08.2019.

Research output: Contribution to journalConference article

Sakakibara, Hikari ; Akimoto, Takashi ; Igarashi, Hitomi ; Nakamura, Shunsuke ; Kimura, Madoka. / The examination of air blowing method and thermal comfort of variable air conditioning system using coanda effect. In: E3S Web of Conferences. 2019 ; Vol. 111.
@article{3774232a485846998fcce5f7e23d98df,
title = "The examination of air blowing method and thermal comfort of variable air conditioning system using coanda effect",
abstract = "The {"}Strategic Energy Plan{"} implemented by the Cabinet of Japan in 2014 strives for zero energy building design for typical new construction by 2030. The present study focuses on a ductless and variable air conditioning system, using the Coanda effect, with the aim of reducing fan power, and saving of resources by reducing the space between the ceiling. In this study, we examined the air blowing method and evaluated thermal comfort using computational fluid dynamics as well as subjective perception of coolness in a midsize office. A draft zone was reduced by extending the interval between conditioned air outlets. However, if the extension of throw length was excessive, hot space would be formed near the air outlets, and there would be a risk of impacting thermal comfort. Moreover, we confirmed that the thermal comfort was generally favourable. In particular, perceived thermal comfort was better at the position in the office where the air flow landed on the upper body of the subjects. On the other hand, it decreased when the influence of the air flow was small, and at the point where air flow landed on the lower body of the subjects.",
author = "Hikari Sakakibara and Takashi Akimoto and Hitomi Igarashi and Shunsuke Nakamura and Madoka Kimura",
year = "2019",
month = "8",
day = "13",
doi = "10.1051/e3sconf/201911101079",
language = "English",
volume = "111",
journal = "E3S Web of Conferences",
issn = "2555-0403",
publisher = "EDP Sciences",

}

TY - JOUR

T1 - The examination of air blowing method and thermal comfort of variable air conditioning system using coanda effect

AU - Sakakibara, Hikari

AU - Akimoto, Takashi

AU - Igarashi, Hitomi

AU - Nakamura, Shunsuke

AU - Kimura, Madoka

PY - 2019/8/13

Y1 - 2019/8/13

N2 - The "Strategic Energy Plan" implemented by the Cabinet of Japan in 2014 strives for zero energy building design for typical new construction by 2030. The present study focuses on a ductless and variable air conditioning system, using the Coanda effect, with the aim of reducing fan power, and saving of resources by reducing the space between the ceiling. In this study, we examined the air blowing method and evaluated thermal comfort using computational fluid dynamics as well as subjective perception of coolness in a midsize office. A draft zone was reduced by extending the interval between conditioned air outlets. However, if the extension of throw length was excessive, hot space would be formed near the air outlets, and there would be a risk of impacting thermal comfort. Moreover, we confirmed that the thermal comfort was generally favourable. In particular, perceived thermal comfort was better at the position in the office where the air flow landed on the upper body of the subjects. On the other hand, it decreased when the influence of the air flow was small, and at the point where air flow landed on the lower body of the subjects.

AB - The "Strategic Energy Plan" implemented by the Cabinet of Japan in 2014 strives for zero energy building design for typical new construction by 2030. The present study focuses on a ductless and variable air conditioning system, using the Coanda effect, with the aim of reducing fan power, and saving of resources by reducing the space between the ceiling. In this study, we examined the air blowing method and evaluated thermal comfort using computational fluid dynamics as well as subjective perception of coolness in a midsize office. A draft zone was reduced by extending the interval between conditioned air outlets. However, if the extension of throw length was excessive, hot space would be formed near the air outlets, and there would be a risk of impacting thermal comfort. Moreover, we confirmed that the thermal comfort was generally favourable. In particular, perceived thermal comfort was better at the position in the office where the air flow landed on the upper body of the subjects. On the other hand, it decreased when the influence of the air flow was small, and at the point where air flow landed on the lower body of the subjects.

UR - http://www.scopus.com/inward/record.url?scp=85071842131&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85071842131&partnerID=8YFLogxK

U2 - 10.1051/e3sconf/201911101079

DO - 10.1051/e3sconf/201911101079

M3 - Conference article

VL - 111

JO - E3S Web of Conferences

JF - E3S Web of Conferences

SN - 2555-0403

M1 - 01079

ER -