The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method

Yoshikazu Koike, Hiroshige Kikura, Sanehiro Wada, Tsuyoshi Taishi, Masanori Aritomi, Michitsugu Mori

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Abstract

An ultrasonic Doppler method (UDM) can achieve high accurate flow rate measurement in underdeveloped flow or transient flow. In the conventional method, the UDM for flow rate measurement requires suspending particles in fluid as reflectors. However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied to the measurement. The authors group has proposed the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The cavitation bubbles inside the pipe are excited by the low frequency Langevin transducer attached to the outside wall. The distribution of the cavitation bubbles have a large influence on the accuracy of the measurement. In this report, the optimum distribution of the cavitation bubbles was examined. The intensity of the harmonic components of the measure sound pressure corresponds to the intensity of cavitaiton bubbles. In order to examine the measurement accuracy of the flow rate against the intensity of caviation bubble, the sound pressure distribution in the cavitation excitation part was measured by the hydrophone.

Original languageEnglish
Title of host publicationProceedings of the IEEE Ultrasonics Symposium
EditorsD.E. Yuhas, S.C. Schneider
Pages1451-1454
Number of pages4
Volume2
Publication statusPublished - 2003
Event2003 IEEE Ultrasonics Symposium - Proceedings - Honolulu, HI, United States
Duration: 2003 Oct 52003 Oct 8

Other

Other2003 IEEE Ultrasonics Symposium - Proceedings
CountryUnited States
CityHonolulu, HI
Period03/10/503/10/8

Fingerprint

Ultrasonic measurement
Bubbles (in fluids)
Cavitation
Flow rate
Ultrasonics
Acoustic waves
Hydrophones
Flow measurement
Pressure distribution
Transducers
Pipe
Fluids
Water

ASJC Scopus subject areas

  • Engineering(all)

Cite this

Koike, Y., Kikura, H., Wada, S., Taishi, T., Aritomi, M., & Mori, M. (2003). The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method. In D. E. Yuhas, & S. C. Schneider (Eds.), Proceedings of the IEEE Ultrasonics Symposium (Vol. 2, pp. 1451-1454)

The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method. / Koike, Yoshikazu; Kikura, Hiroshige; Wada, Sanehiro; Taishi, Tsuyoshi; Aritomi, Masanori; Mori, Michitsugu.

Proceedings of the IEEE Ultrasonics Symposium. ed. / D.E. Yuhas; S.C. Schneider. Vol. 2 2003. p. 1451-1454.

Research output: Chapter in Book/Report/Conference proceedingConference contribution

Koike, Y, Kikura, H, Wada, S, Taishi, T, Aritomi, M & Mori, M 2003, The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method. in DE Yuhas & SC Schneider (eds), Proceedings of the IEEE Ultrasonics Symposium. vol. 2, pp. 1451-1454, 2003 IEEE Ultrasonics Symposium - Proceedings, Honolulu, HI, United States, 03/10/5.
Koike Y, Kikura H, Wada S, Taishi T, Aritomi M, Mori M. The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method. In Yuhas DE, Schneider SC, editors, Proceedings of the IEEE Ultrasonics Symposium. Vol. 2. 2003. p. 1451-1454
Koike, Yoshikazu ; Kikura, Hiroshige ; Wada, Sanehiro ; Taishi, Tsuyoshi ; Aritomi, Masanori ; Mori, Michitsugu. / The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method. Proceedings of the IEEE Ultrasonics Symposium. editor / D.E. Yuhas ; S.C. Schneider. Vol. 2 2003. pp. 1451-1454
@inproceedings{ea80655147e24f2aa230c6b798e150ee,
title = "The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method",
abstract = "An ultrasonic Doppler method (UDM) can achieve high accurate flow rate measurement in underdeveloped flow or transient flow. In the conventional method, the UDM for flow rate measurement requires suspending particles in fluid as reflectors. However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied to the measurement. The authors group has proposed the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The cavitation bubbles inside the pipe are excited by the low frequency Langevin transducer attached to the outside wall. The distribution of the cavitation bubbles have a large influence on the accuracy of the measurement. In this report, the optimum distribution of the cavitation bubbles was examined. The intensity of the harmonic components of the measure sound pressure corresponds to the intensity of cavitaiton bubbles. In order to examine the measurement accuracy of the flow rate against the intensity of caviation bubble, the sound pressure distribution in the cavitation excitation part was measured by the hydrophone.",
author = "Yoshikazu Koike and Hiroshige Kikura and Sanehiro Wada and Tsuyoshi Taishi and Masanori Aritomi and Michitsugu Mori",
year = "2003",
language = "English",
volume = "2",
pages = "1451--1454",
editor = "D.E. Yuhas and S.C. Schneider",
booktitle = "Proceedings of the IEEE Ultrasonics Symposium",

}

TY - GEN

T1 - The optimum distribution of cavitation bubbles for a flow rate measurement using ultrasonic doppler method

AU - Koike, Yoshikazu

AU - Kikura, Hiroshige

AU - Wada, Sanehiro

AU - Taishi, Tsuyoshi

AU - Aritomi, Masanori

AU - Mori, Michitsugu

PY - 2003

Y1 - 2003

N2 - An ultrasonic Doppler method (UDM) can achieve high accurate flow rate measurement in underdeveloped flow or transient flow. In the conventional method, the UDM for flow rate measurement requires suspending particles in fluid as reflectors. However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied to the measurement. The authors group has proposed the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The cavitation bubbles inside the pipe are excited by the low frequency Langevin transducer attached to the outside wall. The distribution of the cavitation bubbles have a large influence on the accuracy of the measurement. In this report, the optimum distribution of the cavitation bubbles was examined. The intensity of the harmonic components of the measure sound pressure corresponds to the intensity of cavitaiton bubbles. In order to examine the measurement accuracy of the flow rate against the intensity of caviation bubble, the sound pressure distribution in the cavitation excitation part was measured by the hydrophone.

AB - An ultrasonic Doppler method (UDM) can achieve high accurate flow rate measurement in underdeveloped flow or transient flow. In the conventional method, the UDM for flow rate measurement requires suspending particles in fluid as reflectors. However, in some applications, for example, a flow rate measurement in clean water, any particle does not exist in the flow and hence, the conventional UDM cannot be applied to the measurement. The authors group has proposed the ultrasonic cavitation bubbles as reflectors in the flow measurement by UDM. The cavitation bubbles inside the pipe are excited by the low frequency Langevin transducer attached to the outside wall. The distribution of the cavitation bubbles have a large influence on the accuracy of the measurement. In this report, the optimum distribution of the cavitation bubbles was examined. The intensity of the harmonic components of the measure sound pressure corresponds to the intensity of cavitaiton bubbles. In order to examine the measurement accuracy of the flow rate against the intensity of caviation bubble, the sound pressure distribution in the cavitation excitation part was measured by the hydrophone.

UR - http://www.scopus.com/inward/record.url?scp=4143069536&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=4143069536&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:4143069536

VL - 2

SP - 1451

EP - 1454

BT - Proceedings of the IEEE Ultrasonics Symposium

A2 - Yuhas, D.E.

A2 - Schneider, S.C.

ER -