Water cut-off performance of H-Jointed steel pipe sheet piles with H-H joints attaching water-swelling materials

Shinya Inazumi, Makoto Kimura, Toshimitsu Kakuda, Masakatsu Kobayashi

Research output: Contribution to journalArticle

4 Citations (Scopus)

Abstract

In this research, under various conditions, we evaluate the water cut-off performance of H-jointed steel pipe sheet piles (SPSPs) with the H-H joints attaching water-swelling materials which are components of SPSPs for water cut-off in a coastal waste landfill site. Specifically, we research the water cut-off performance when these H-H joints have foreign particles, when they are in a wet-dry cyclic condition, and when the water-swelling material has deteriorated. As a result of this research, it has been found that in any of the above cases, H-jointed SPSPs with H-H joints attaching water-swelling materials are capable of providing water cut-off performance, and meet seepage control work standards as long as they are under less than certain pressure levels to be considered in coastal waste landfill sites. Also, it has been proved that the above conditions do not affect the water cut-off performance of H-jointed SPSPs with H-H joints attaching water-swelling materials.

Original languageEnglish
Pages (from-to)1019-1035
Number of pages17
JournalSoils and Foundations
Volume51
Issue number6
DOIs
Publication statusPublished - 2011 Dec
Externally publishedYes

Fingerprint

Steel pipe
swelling
Piles
Swelling
pile
pipe
steel
Hydrogen
Water
water
landfill
Land fill
material
seepage
Seepage

Keywords

  • Cutoff wall
  • H-jointed steel pipe sheet pile with H-H joint
  • Hydraulic conductivity
  • Joint
  • Permeability test
  • Steel pipe sheet pile
  • Waste landfill site
  • Water-swelling material

ASJC Scopus subject areas

  • Civil and Structural Engineering
  • Geotechnical Engineering and Engineering Geology

Cite this

Water cut-off performance of H-Jointed steel pipe sheet piles with H-H joints attaching water-swelling materials. / Inazumi, Shinya; Kimura, Makoto; Kakuda, Toshimitsu; Kobayashi, Masakatsu.

In: Soils and Foundations, Vol. 51, No. 6, 12.2011, p. 1019-1035.

Research output: Contribution to journalArticle

Inazumi, Shinya ; Kimura, Makoto ; Kakuda, Toshimitsu ; Kobayashi, Masakatsu. / Water cut-off performance of H-Jointed steel pipe sheet piles with H-H joints attaching water-swelling materials. In: Soils and Foundations. 2011 ; Vol. 51, No. 6. pp. 1019-1035.
@article{e6c98a6fb3094c21aede76d4619e7f79,
title = "Water cut-off performance of H-Jointed steel pipe sheet piles with H-H joints attaching water-swelling materials",
abstract = "In this research, under various conditions, we evaluate the water cut-off performance of H-jointed steel pipe sheet piles (SPSPs) with the H-H joints attaching water-swelling materials which are components of SPSPs for water cut-off in a coastal waste landfill site. Specifically, we research the water cut-off performance when these H-H joints have foreign particles, when they are in a wet-dry cyclic condition, and when the water-swelling material has deteriorated. As a result of this research, it has been found that in any of the above cases, H-jointed SPSPs with H-H joints attaching water-swelling materials are capable of providing water cut-off performance, and meet seepage control work standards as long as they are under less than certain pressure levels to be considered in coastal waste landfill sites. Also, it has been proved that the above conditions do not affect the water cut-off performance of H-jointed SPSPs with H-H joints attaching water-swelling materials.",
keywords = "Cutoff wall, H-jointed steel pipe sheet pile with H-H joint, Hydraulic conductivity, Joint, Permeability test, Steel pipe sheet pile, Waste landfill site, Water-swelling material",
author = "Shinya Inazumi and Makoto Kimura and Toshimitsu Kakuda and Masakatsu Kobayashi",
year = "2011",
month = "12",
doi = "10.3208/sandf.51.1019",
language = "English",
volume = "51",
pages = "1019--1035",
journal = "Soils and Foundations",
issn = "0038-0806",
publisher = "Japanese Geotechnical Society",
number = "6",

}

TY - JOUR

T1 - Water cut-off performance of H-Jointed steel pipe sheet piles with H-H joints attaching water-swelling materials

AU - Inazumi, Shinya

AU - Kimura, Makoto

AU - Kakuda, Toshimitsu

AU - Kobayashi, Masakatsu

PY - 2011/12

Y1 - 2011/12

N2 - In this research, under various conditions, we evaluate the water cut-off performance of H-jointed steel pipe sheet piles (SPSPs) with the H-H joints attaching water-swelling materials which are components of SPSPs for water cut-off in a coastal waste landfill site. Specifically, we research the water cut-off performance when these H-H joints have foreign particles, when they are in a wet-dry cyclic condition, and when the water-swelling material has deteriorated. As a result of this research, it has been found that in any of the above cases, H-jointed SPSPs with H-H joints attaching water-swelling materials are capable of providing water cut-off performance, and meet seepage control work standards as long as they are under less than certain pressure levels to be considered in coastal waste landfill sites. Also, it has been proved that the above conditions do not affect the water cut-off performance of H-jointed SPSPs with H-H joints attaching water-swelling materials.

AB - In this research, under various conditions, we evaluate the water cut-off performance of H-jointed steel pipe sheet piles (SPSPs) with the H-H joints attaching water-swelling materials which are components of SPSPs for water cut-off in a coastal waste landfill site. Specifically, we research the water cut-off performance when these H-H joints have foreign particles, when they are in a wet-dry cyclic condition, and when the water-swelling material has deteriorated. As a result of this research, it has been found that in any of the above cases, H-jointed SPSPs with H-H joints attaching water-swelling materials are capable of providing water cut-off performance, and meet seepage control work standards as long as they are under less than certain pressure levels to be considered in coastal waste landfill sites. Also, it has been proved that the above conditions do not affect the water cut-off performance of H-jointed SPSPs with H-H joints attaching water-swelling materials.

KW - Cutoff wall

KW - H-jointed steel pipe sheet pile with H-H joint

KW - Hydraulic conductivity

KW - Joint

KW - Permeability test

KW - Steel pipe sheet pile

KW - Waste landfill site

KW - Water-swelling material

UR - http://www.scopus.com/inward/record.url?scp=84866867490&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84866867490&partnerID=8YFLogxK

U2 - 10.3208/sandf.51.1019

DO - 10.3208/sandf.51.1019

M3 - Article

AN - SCOPUS:84866867490

VL - 51

SP - 1019

EP - 1035

JO - Soils and Foundations

JF - Soils and Foundations

SN - 0038-0806

IS - 6

ER -