TY - JOUR
T1 - A Novel Control Method on Single Phase Grid Connectable Inverter with Hilbert Transformer
AU - Saitou, Makoto
AU - Shimizu, Tosihisa
PY - 2001/9/1
Y1 - 2001/9/1
N2 - In order to control the power factor on a single-phase grid connectable inverter, a novel control method with Hilbert transformer is presented in this paper. Using Hilbert transformer theory, the d-q transformation on singlephase utility line current and utility voltage can be realized, and active power and reactive power can be controlled separately without offset. The effectiveness of the proposed control method is verified by the computer simulator, and some significant characteristics are also shown in this paper.
AB - In order to control the power factor on a single-phase grid connectable inverter, a novel control method with Hilbert transformer is presented in this paper. Using Hilbert transformer theory, the d-q transformation on singlephase utility line current and utility voltage can be realized, and active power and reactive power can be controlled separately without offset. The effectiveness of the proposed control method is verified by the computer simulator, and some significant characteristics are also shown in this paper.
UR - http://www.scopus.com/inward/record.url?scp=79959900033&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=79959900033&partnerID=8YFLogxK
U2 - 10.1541/ieejias.121.1089
DO - 10.1541/ieejias.121.1089
M3 - Article
AN - SCOPUS:79959900033
SN - 0913-6339
VL - 121
SP - 1089
EP - 1090
JO - IEEJ Transactions on Industry Applications
JF - IEEJ Transactions on Industry Applications
IS - 10
ER -