Degradation of the organic coating film on the carbon steel has been investigated by dynamic impedance measurements. Since the permeation of water into the coating progresses in short period after the immersion, the time-stability of the electrode system is not satisfied while measuring the electrochemical impedance. As the result, the impedance spectrum in the low frequency region is distorted with the electrode that does not satisfy the time-stability. In the present paper, a dynamic impedance spectroscopy is applied to the electrode without the time-stability, and the distortion of impedance spectrum in the low frequency region is compensated. The degradation process of the coated metal was analyzed by the curve-fitting of the compensated impedance spectra with the equivalent circuit.

元の言語English
ページ(範囲)3802-3811
ページ数10
ジャーナルCorrosion Science
48
発行部数11
DOI
出版物ステータスPublished - 2006 11

Fingerprint

Degradation
Electrodes
Organic coatings
Curve fitting
Permeation
Equivalent circuits
Carbon steel
Metals
Spectroscopy
Coatings
Water

ASJC Scopus subject areas

  • Materials Science(all)
  • Metals and Alloys

これを引用

Analysis on organic film degradation by dynamic impedance measurements. / Itagaki, Masayuki; Ono, Akira; Watanabe, Kunihiro; Katayama, Hideki; Noda, Kazuhiko.

:: Corrosion Science, 巻 48, 番号 11, 11.2006, p. 3802-3811.

研究成果: Article

Itagaki, Masayuki ; Ono, Akira ; Watanabe, Kunihiro ; Katayama, Hideki ; Noda, Kazuhiko. / Analysis on organic film degradation by dynamic impedance measurements. :: Corrosion Science. 2006 ; 巻 48, 番号 11. pp. 3802-3811.
@article{66ec8b9122a94521bca1fba263be9881,
title = "Analysis on organic film degradation by dynamic impedance measurements",
abstract = "Degradation of the organic coating film on the carbon steel has been investigated by dynamic impedance measurements. Since the permeation of water into the coating progresses in short period after the immersion, the time-stability of the electrode system is not satisfied while measuring the electrochemical impedance. As the result, the impedance spectrum in the low frequency region is distorted with the electrode that does not satisfy the time-stability. In the present paper, a dynamic impedance spectroscopy is applied to the electrode without the time-stability, and the distortion of impedance spectrum in the low frequency region is compensated. The degradation process of the coated metal was analyzed by the curve-fitting of the compensated impedance spectra with the equivalent circuit.",
keywords = "Degradation, Dynamic impedance, EIS, Organic film",
author = "Masayuki Itagaki and Akira Ono and Kunihiro Watanabe and Hideki Katayama and Kazuhiko Noda",
year = "2006",
month = "11",
doi = "10.1016/j.corsci.2006.01.011",
language = "English",
volume = "48",
pages = "3802--3811",
journal = "Corrosion Science",
issn = "0010-938X",
publisher = "Elsevier Limited",
number = "11",

}

TY - JOUR

T1 - Analysis on organic film degradation by dynamic impedance measurements

AU - Itagaki, Masayuki

AU - Ono, Akira

AU - Watanabe, Kunihiro

AU - Katayama, Hideki

AU - Noda, Kazuhiko

PY - 2006/11

Y1 - 2006/11

N2 - Degradation of the organic coating film on the carbon steel has been investigated by dynamic impedance measurements. Since the permeation of water into the coating progresses in short period after the immersion, the time-stability of the electrode system is not satisfied while measuring the electrochemical impedance. As the result, the impedance spectrum in the low frequency region is distorted with the electrode that does not satisfy the time-stability. In the present paper, a dynamic impedance spectroscopy is applied to the electrode without the time-stability, and the distortion of impedance spectrum in the low frequency region is compensated. The degradation process of the coated metal was analyzed by the curve-fitting of the compensated impedance spectra with the equivalent circuit.

AB - Degradation of the organic coating film on the carbon steel has been investigated by dynamic impedance measurements. Since the permeation of water into the coating progresses in short period after the immersion, the time-stability of the electrode system is not satisfied while measuring the electrochemical impedance. As the result, the impedance spectrum in the low frequency region is distorted with the electrode that does not satisfy the time-stability. In the present paper, a dynamic impedance spectroscopy is applied to the electrode without the time-stability, and the distortion of impedance spectrum in the low frequency region is compensated. The degradation process of the coated metal was analyzed by the curve-fitting of the compensated impedance spectra with the equivalent circuit.

KW - Degradation

KW - Dynamic impedance

KW - EIS

KW - Organic film

UR - http://www.scopus.com/inward/record.url?scp=33750053268&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33750053268&partnerID=8YFLogxK

U2 - 10.1016/j.corsci.2006.01.011

DO - 10.1016/j.corsci.2006.01.011

M3 - Article

AN - SCOPUS:33750053268

VL - 48

SP - 3802

EP - 3811

JO - Corrosion Science

JF - Corrosion Science

SN - 0010-938X

IS - 11

ER -