Communication performance of IC-tags installed inside large-size concrete specimens

Hisashi Sugiyama, Hideaki Sumikura, Takaaki Ohkubo, Junko Koga, Tsutomu Hirade

研究成果: Article

抄録

It is important to develop an information traceability system on the process of concrete production. One method is to record the information about the concrete production with IC-tags, and to install them inside the concrete. This method has a characteristic to keep the information inside the concrete itself. On the other hand, this method requires communication performance between IC-tags inside the concrete and the reader outside the concrete. The communication performance of IC-tags installed inside the small-size specimens was clarified in our previous study. This paper describes a study on the communication performance of several types of IC-tags installed inside the large-size concrete specimens.

元の言語English
ページ(範囲)5-10
ページ数6
ジャーナルAIJ Journal of Technology and Design
17
発行部数35
DOI
出版物ステータスPublished - 2011 12 1
外部発表Yes

Fingerprint

Concretes
Communication
Information systems

ASJC Scopus subject areas

  • Building and Construction
  • Architecture

これを引用

Communication performance of IC-tags installed inside large-size concrete specimens. / Sugiyama, Hisashi; Sumikura, Hideaki; Ohkubo, Takaaki; Koga, Junko; Hirade, Tsutomu.

:: AIJ Journal of Technology and Design, 巻 17, 番号 35, 01.12.2011, p. 5-10.

研究成果: Article

Sugiyama, Hisashi ; Sumikura, Hideaki ; Ohkubo, Takaaki ; Koga, Junko ; Hirade, Tsutomu. / Communication performance of IC-tags installed inside large-size concrete specimens. :: AIJ Journal of Technology and Design. 2011 ; 巻 17, 番号 35. pp. 5-10.
@article{0f969b1542c54e02bb2022fa1bb2779b,
title = "Communication performance of IC-tags installed inside large-size concrete specimens",
abstract = "It is important to develop an information traceability system on the process of concrete production. One method is to record the information about the concrete production with IC-tags, and to install them inside the concrete. This method has a characteristic to keep the information inside the concrete itself. On the other hand, this method requires communication performance between IC-tags inside the concrete and the reader outside the concrete. The communication performance of IC-tags installed inside the small-size specimens was clarified in our previous study. This paper describes a study on the communication performance of several types of IC-tags installed inside the large-size concrete specimens.",
keywords = "Communication performance, Concrete, Embedding depth, IC-tag, Traceability",
author = "Hisashi Sugiyama and Hideaki Sumikura and Takaaki Ohkubo and Junko Koga and Tsutomu Hirade",
year = "2011",
month = "12",
day = "1",
doi = "10.3130/aijt.17.5",
language = "English",
volume = "17",
pages = "5--10",
journal = "AIJ Journal of Technology and Design",
issn = "1341-9463",
publisher = "Architectural Institute of Japan",
number = "35",

}

TY - JOUR

T1 - Communication performance of IC-tags installed inside large-size concrete specimens

AU - Sugiyama, Hisashi

AU - Sumikura, Hideaki

AU - Ohkubo, Takaaki

AU - Koga, Junko

AU - Hirade, Tsutomu

PY - 2011/12/1

Y1 - 2011/12/1

N2 - It is important to develop an information traceability system on the process of concrete production. One method is to record the information about the concrete production with IC-tags, and to install them inside the concrete. This method has a characteristic to keep the information inside the concrete itself. On the other hand, this method requires communication performance between IC-tags inside the concrete and the reader outside the concrete. The communication performance of IC-tags installed inside the small-size specimens was clarified in our previous study. This paper describes a study on the communication performance of several types of IC-tags installed inside the large-size concrete specimens.

AB - It is important to develop an information traceability system on the process of concrete production. One method is to record the information about the concrete production with IC-tags, and to install them inside the concrete. This method has a characteristic to keep the information inside the concrete itself. On the other hand, this method requires communication performance between IC-tags inside the concrete and the reader outside the concrete. The communication performance of IC-tags installed inside the small-size specimens was clarified in our previous study. This paper describes a study on the communication performance of several types of IC-tags installed inside the large-size concrete specimens.

KW - Communication performance

KW - Concrete

KW - Embedding depth

KW - IC-tag

KW - Traceability

UR - http://www.scopus.com/inward/record.url?scp=84856967263&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84856967263&partnerID=8YFLogxK

U2 - 10.3130/aijt.17.5

DO - 10.3130/aijt.17.5

M3 - Article

AN - SCOPUS:84856967263

VL - 17

SP - 5

EP - 10

JO - AIJ Journal of Technology and Design

JF - AIJ Journal of Technology and Design

SN - 1341-9463

IS - 35