Comparison between monte carlo simulation codes for emulsion chambers

K. Yanagisawa, Kenji Yoshida, Y. Komori, T. Kobayashi, J. Nishimura

研究成果: Conference contribution

抄録

Cosmic-ray electron observations in the energy range from 30 GeV to 3 TeV have been performed by using balloon-borne emulsion chambers. The emulsion chamber is an excellent imaging detector with a high position resolution of 1µm. This imaging capability enables the emulsion chamber to identify electrons against gamma rays and protons, determine electron energies, and be a thin and low mass detector. The performance of the emulsion chamber was examined by Monte Carlo simulations of Geant4 and EPICS with the results of accelerator beam tests of electrons in 50 GeV – 250 GeV at CERN-SPS. In order to evaluate the possible systematic differences, especially at energies greater than 250 GeV, we made a comparison between completely different simulation codes of Geant4 and EPICS. As the results, we confirmed that the systematic differences are 1 – 3 % for the integral track lengths, which are sufficiently-small for the energy determinations with the emulsion chambers.

元の言語English
ホスト出版物のタイトルProceedings of the 33rd International Cosmic Rays Conference, ICRC 2013
出版者Sociedade Brasileira de Fisica
2013-October
ISBN(電子版)9788589064293
出版物ステータスPublished - 2013 1 1
イベント33rd International Cosmic Rays Conference, ICRC 2013 - Rio de Janeiro, Brazil
継続期間: 2013 7 22013 7 9

Other

Other33rd International Cosmic Rays Conference, ICRC 2013
Brazil
Rio de Janeiro
期間13/7/213/7/9

Fingerprint

emulsions
chambers
simulation
electrons
detectors
balloons
energy
cosmic rays
accelerators
gamma rays
electron energy
protons

ASJC Scopus subject areas

  • Nuclear and High Energy Physics

これを引用

Yanagisawa, K., Yoshida, K., Komori, Y., Kobayashi, T., & Nishimura, J. (2013). Comparison between monte carlo simulation codes for emulsion chambers. : Proceedings of the 33rd International Cosmic Rays Conference, ICRC 2013 (巻 2013-October). Sociedade Brasileira de Fisica.

Comparison between monte carlo simulation codes for emulsion chambers. / Yanagisawa, K.; Yoshida, Kenji; Komori, Y.; Kobayashi, T.; Nishimura, J.

Proceedings of the 33rd International Cosmic Rays Conference, ICRC 2013. 巻 2013-October Sociedade Brasileira de Fisica, 2013.

研究成果: Conference contribution

Yanagisawa, K, Yoshida, K, Komori, Y, Kobayashi, T & Nishimura, J 2013, Comparison between monte carlo simulation codes for emulsion chambers. : Proceedings of the 33rd International Cosmic Rays Conference, ICRC 2013. 巻. 2013-October, Sociedade Brasileira de Fisica, 33rd International Cosmic Rays Conference, ICRC 2013, Rio de Janeiro, Brazil, 13/7/2.
Yanagisawa K, Yoshida K, Komori Y, Kobayashi T, Nishimura J. Comparison between monte carlo simulation codes for emulsion chambers. : Proceedings of the 33rd International Cosmic Rays Conference, ICRC 2013. 巻 2013-October. Sociedade Brasileira de Fisica. 2013
Yanagisawa, K. ; Yoshida, Kenji ; Komori, Y. ; Kobayashi, T. ; Nishimura, J. / Comparison between monte carlo simulation codes for emulsion chambers. Proceedings of the 33rd International Cosmic Rays Conference, ICRC 2013. 巻 2013-October Sociedade Brasileira de Fisica, 2013.
@inproceedings{80f55b61781446fcb65d542b837ca35b,
title = "Comparison between monte carlo simulation codes for emulsion chambers",
abstract = "Cosmic-ray electron observations in the energy range from 30 GeV to 3 TeV have been performed by using balloon-borne emulsion chambers. The emulsion chamber is an excellent imaging detector with a high position resolution of 1µm. This imaging capability enables the emulsion chamber to identify electrons against gamma rays and protons, determine electron energies, and be a thin and low mass detector. The performance of the emulsion chamber was examined by Monte Carlo simulations of Geant4 and EPICS with the results of accelerator beam tests of electrons in 50 GeV – 250 GeV at CERN-SPS. In order to evaluate the possible systematic differences, especially at energies greater than 250 GeV, we made a comparison between completely different simulation codes of Geant4 and EPICS. As the results, we confirmed that the systematic differences are 1 – 3 {\%} for the integral track lengths, which are sufficiently-small for the energy determinations with the emulsion chambers.",
keywords = "Electron, Emulsion chamber, EPICS, Geant4, Mont-Carlo simulation",
author = "K. Yanagisawa and Kenji Yoshida and Y. Komori and T. Kobayashi and J. Nishimura",
year = "2013",
month = "1",
day = "1",
language = "English",
volume = "2013-October",
booktitle = "Proceedings of the 33rd International Cosmic Rays Conference, ICRC 2013",
publisher = "Sociedade Brasileira de Fisica",
address = "Brazil",

}

TY - GEN

T1 - Comparison between monte carlo simulation codes for emulsion chambers

AU - Yanagisawa, K.

AU - Yoshida, Kenji

AU - Komori, Y.

AU - Kobayashi, T.

AU - Nishimura, J.

PY - 2013/1/1

Y1 - 2013/1/1

N2 - Cosmic-ray electron observations in the energy range from 30 GeV to 3 TeV have been performed by using balloon-borne emulsion chambers. The emulsion chamber is an excellent imaging detector with a high position resolution of 1µm. This imaging capability enables the emulsion chamber to identify electrons against gamma rays and protons, determine electron energies, and be a thin and low mass detector. The performance of the emulsion chamber was examined by Monte Carlo simulations of Geant4 and EPICS with the results of accelerator beam tests of electrons in 50 GeV – 250 GeV at CERN-SPS. In order to evaluate the possible systematic differences, especially at energies greater than 250 GeV, we made a comparison between completely different simulation codes of Geant4 and EPICS. As the results, we confirmed that the systematic differences are 1 – 3 % for the integral track lengths, which are sufficiently-small for the energy determinations with the emulsion chambers.

AB - Cosmic-ray electron observations in the energy range from 30 GeV to 3 TeV have been performed by using balloon-borne emulsion chambers. The emulsion chamber is an excellent imaging detector with a high position resolution of 1µm. This imaging capability enables the emulsion chamber to identify electrons against gamma rays and protons, determine electron energies, and be a thin and low mass detector. The performance of the emulsion chamber was examined by Monte Carlo simulations of Geant4 and EPICS with the results of accelerator beam tests of electrons in 50 GeV – 250 GeV at CERN-SPS. In order to evaluate the possible systematic differences, especially at energies greater than 250 GeV, we made a comparison between completely different simulation codes of Geant4 and EPICS. As the results, we confirmed that the systematic differences are 1 – 3 % for the integral track lengths, which are sufficiently-small for the energy determinations with the emulsion chambers.

KW - Electron

KW - Emulsion chamber

KW - EPICS

KW - Geant4

KW - Mont-Carlo simulation

UR - http://www.scopus.com/inward/record.url?scp=85052326047&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85052326047&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:85052326047

VL - 2013-October

BT - Proceedings of the 33rd International Cosmic Rays Conference, ICRC 2013

PB - Sociedade Brasileira de Fisica

ER -