Malformed ears of neonates can be effectively treated by employing a suitably shaped orthosis Orthoses made of nitinol shape memory alloy wire and a computer-assisted design system to manufacture the orthosis have been developed. By adding the detour part to the shape of the orthosis, contact force between the orthosis and auricle can be relaxed. The results of insertion experiment and simulation using urethane rubber plate and six orthoses with different detour distances showed that the larger the distance, the contact force becomes smaller when the detour distance was more than 16 mm. Also finite element analysis result using auricular model showed that the contact force can be controlled by the detour dis tance. As for the evaluated case, the longer the distance, the contact force becomes smaller when the detour distance was more than 8 mm. The detoured type orthoses were applied to the treatment of cryptotia, and treated effectively within a year.

元の言語English
ページ(範囲)321-323
ページ数3
ジャーナルInternational journal of computer assisted radiology and surgery
1
発行部数SUPPL. 7
DOI
出版物ステータスPublished - 2006 6
外部発表Yes

Fingerprint

Shape memory effect
Rubber
Wire
Finite element method
Experiments

ASJC Scopus subject areas

  • Transplantation
  • Radiology Nuclear Medicine and imaging

これを引用

Contact force controlled orthoses made of nitinol shape memory alloy wire for the treatment of malformed ears. / Hanafusa, Akihiko; Takahashi, H.; Sekiguchi, Y.; Nozaki, M.; Dohi, T.

:: International journal of computer assisted radiology and surgery, 巻 1, 番号 SUPPL. 7, 06.2006, p. 321-323.

研究成果: Article

@article{dfaba46c66cf40a1bfae56efe47a5183,
title = "Contact force controlled orthoses made of nitinol shape memory alloy wire for the treatment of malformed ears",
abstract = "Malformed ears of neonates can be effectively treated by employing a suitably shaped orthosis Orthoses made of nitinol shape memory alloy wire and a computer-assisted design system to manufacture the orthosis have been developed. By adding the detour part to the shape of the orthosis, contact force between the orthosis and auricle can be relaxed. The results of insertion experiment and simulation using urethane rubber plate and six orthoses with different detour distances showed that the larger the distance, the contact force becomes smaller when the detour distance was more than 16 mm. Also finite element analysis result using auricular model showed that the contact force can be controlled by the detour dis tance. As for the evaluated case, the longer the distance, the contact force becomes smaller when the detour distance was more than 8 mm. The detoured type orthoses were applied to the treatment of cryptotia, and treated effectively within a year.",
keywords = "Finite element analysis, Malformed ears, Orthosis, Shape memory alloy wire",
author = "Akihiko Hanafusa and H. Takahashi and Y. Sekiguchi and M. Nozaki and T. Dohi",
year = "2006",
month = "6",
doi = "10.1007/s11548-007-0071-y",
language = "English",
volume = "1",
pages = "321--323",
journal = "Computer-Assisted Radiology and Surgery",
issn = "1861-6410",
publisher = "Springer Verlag",
number = "SUPPL. 7",

}

TY - JOUR

T1 - Contact force controlled orthoses made of nitinol shape memory alloy wire for the treatment of malformed ears

AU - Hanafusa, Akihiko

AU - Takahashi, H.

AU - Sekiguchi, Y.

AU - Nozaki, M.

AU - Dohi, T.

PY - 2006/6

Y1 - 2006/6

N2 - Malformed ears of neonates can be effectively treated by employing a suitably shaped orthosis Orthoses made of nitinol shape memory alloy wire and a computer-assisted design system to manufacture the orthosis have been developed. By adding the detour part to the shape of the orthosis, contact force between the orthosis and auricle can be relaxed. The results of insertion experiment and simulation using urethane rubber plate and six orthoses with different detour distances showed that the larger the distance, the contact force becomes smaller when the detour distance was more than 16 mm. Also finite element analysis result using auricular model showed that the contact force can be controlled by the detour dis tance. As for the evaluated case, the longer the distance, the contact force becomes smaller when the detour distance was more than 8 mm. The detoured type orthoses were applied to the treatment of cryptotia, and treated effectively within a year.

AB - Malformed ears of neonates can be effectively treated by employing a suitably shaped orthosis Orthoses made of nitinol shape memory alloy wire and a computer-assisted design system to manufacture the orthosis have been developed. By adding the detour part to the shape of the orthosis, contact force between the orthosis and auricle can be relaxed. The results of insertion experiment and simulation using urethane rubber plate and six orthoses with different detour distances showed that the larger the distance, the contact force becomes smaller when the detour distance was more than 16 mm. Also finite element analysis result using auricular model showed that the contact force can be controlled by the detour dis tance. As for the evaluated case, the longer the distance, the contact force becomes smaller when the detour distance was more than 8 mm. The detoured type orthoses were applied to the treatment of cryptotia, and treated effectively within a year.

KW - Finite element analysis

KW - Malformed ears

KW - Orthosis

KW - Shape memory alloy wire

UR - http://www.scopus.com/inward/record.url?scp=33748955183&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=33748955183&partnerID=8YFLogxK