Cuffless Blood Pressure Estimation Only an iPhone: Investigation on Cold Pressor Tests

Ippei Harada, Noriyuki Mochizuki, Peter Rolfe, Masahiro Shibata, Takehiro Yamakoshi

研究成果: Conference contribution

抄録

Cuffless blood pressure (BP) measurement is an all-inclusive term for a method that aims to measure BP without using a cuff. In our previous article, we reported the development of a simple cuffless technique based on the haemodynamic expression, using only pulse rate (PR) and modified normalized pulse volume (mNPV) that can be measured using only a smartphone. The stressor used in our previous article was the cardiac-dominant pattern (mental arithmetic); however, here we have experimented with another stressor, namely, a vascular-dominant pattern in a cold pressor test, to verify this theory in 7 healthy young males and 6 healthy young females (N = 22). As a result, the mean arterial pressure accuracy was improved (r = 0.727) compared with that achieved in the previous study.

元の言語English
ホスト出版物のタイトル15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019
編集者Jorge Henriques, Paulo de Carvalho, Nuno Neves
出版者Springer
ページ874-877
ページ数4
ISBN(印刷物)9783030316341
DOI
出版物ステータスPublished - 2020 1 1
イベント15th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2019 - Coimbra, Portugal
継続期間: 2019 9 262019 9 28

出版物シリーズ

名前IFMBE Proceedings
76
ISSN(印刷物)1680-0737
ISSN(電子版)1433-9277

Conference

Conference15th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2019
Portugal
Coimbra
期間19/9/2619/9/28

Fingerprint

Blood pressure
Smartphones
Hemodynamics
Pressure measurement

ASJC Scopus subject areas

  • Bioengineering
  • Biomedical Engineering

これを引用

Harada, I., Mochizuki, N., Rolfe, P., Shibata, M., & Yamakoshi, T. (2020). Cuffless Blood Pressure Estimation Only an iPhone: Investigation on Cold Pressor Tests. : J. Henriques, P. de Carvalho, & N. Neves (版), 15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019 (pp. 874-877). (IFMBE Proceedings; 巻数 76). Springer. https://doi.org/10.1007/978-3-030-31635-8_105

Cuffless Blood Pressure Estimation Only an iPhone : Investigation on Cold Pressor Tests. / Harada, Ippei; Mochizuki, Noriyuki; Rolfe, Peter; Shibata, Masahiro; Yamakoshi, Takehiro.

15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019. 版 / Jorge Henriques; Paulo de Carvalho; Nuno Neves. Springer, 2020. p. 874-877 (IFMBE Proceedings; 巻 76).

研究成果: Conference contribution

Harada, I, Mochizuki, N, Rolfe, P, Shibata, M & Yamakoshi, T 2020, Cuffless Blood Pressure Estimation Only an iPhone: Investigation on Cold Pressor Tests. : J Henriques, P de Carvalho & N Neves (版), 15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019. IFMBE Proceedings, 巻. 76, Springer, pp. 874-877, 15th Mediterranean Conference on Medical and Biological Engineering and Computing, MEDICON 2019, Coimbra, Portugal, 19/9/26. https://doi.org/10.1007/978-3-030-31635-8_105
Harada I, Mochizuki N, Rolfe P, Shibata M, Yamakoshi T. Cuffless Blood Pressure Estimation Only an iPhone: Investigation on Cold Pressor Tests. : Henriques J, de Carvalho P, Neves N, 編集者, 15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019. Springer. 2020. p. 874-877. (IFMBE Proceedings). https://doi.org/10.1007/978-3-030-31635-8_105
Harada, Ippei ; Mochizuki, Noriyuki ; Rolfe, Peter ; Shibata, Masahiro ; Yamakoshi, Takehiro. / Cuffless Blood Pressure Estimation Only an iPhone : Investigation on Cold Pressor Tests. 15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019. 編集者 / Jorge Henriques ; Paulo de Carvalho ; Nuno Neves. Springer, 2020. pp. 874-877 (IFMBE Proceedings).
@inproceedings{698e0e223662421d9065ef5f0fee2b64,
title = "Cuffless Blood Pressure Estimation Only an iPhone: Investigation on Cold Pressor Tests",
abstract = "Cuffless blood pressure (BP) measurement is an all-inclusive term for a method that aims to measure BP without using a cuff. In our previous article, we reported the development of a simple cuffless technique based on the haemodynamic expression, using only pulse rate (PR) and modified normalized pulse volume (mNPV) that can be measured using only a smartphone. The stressor used in our previous article was the cardiac-dominant pattern (mental arithmetic); however, here we have experimented with another stressor, namely, a vascular-dominant pattern in a cold pressor test, to verify this theory in 7 healthy young males and 6 healthy young females (N = 22). As a result, the mean arterial pressure accuracy was improved (r = 0.727) compared with that achieved in the previous study.",
keywords = "Circulatory equation, Cuffless blood pressure, Heamodynamic",
author = "Ippei Harada and Noriyuki Mochizuki and Peter Rolfe and Masahiro Shibata and Takehiro Yamakoshi",
year = "2020",
month = "1",
day = "1",
doi = "10.1007/978-3-030-31635-8_105",
language = "English",
isbn = "9783030316341",
series = "IFMBE Proceedings",
publisher = "Springer",
pages = "874--877",
editor = "Jorge Henriques and {de Carvalho}, Paulo and Nuno Neves",
booktitle = "15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019",

}

TY - GEN

T1 - Cuffless Blood Pressure Estimation Only an iPhone

T2 - Investigation on Cold Pressor Tests

AU - Harada, Ippei

AU - Mochizuki, Noriyuki

AU - Rolfe, Peter

AU - Shibata, Masahiro

AU - Yamakoshi, Takehiro

PY - 2020/1/1

Y1 - 2020/1/1

N2 - Cuffless blood pressure (BP) measurement is an all-inclusive term for a method that aims to measure BP without using a cuff. In our previous article, we reported the development of a simple cuffless technique based on the haemodynamic expression, using only pulse rate (PR) and modified normalized pulse volume (mNPV) that can be measured using only a smartphone. The stressor used in our previous article was the cardiac-dominant pattern (mental arithmetic); however, here we have experimented with another stressor, namely, a vascular-dominant pattern in a cold pressor test, to verify this theory in 7 healthy young males and 6 healthy young females (N = 22). As a result, the mean arterial pressure accuracy was improved (r = 0.727) compared with that achieved in the previous study.

AB - Cuffless blood pressure (BP) measurement is an all-inclusive term for a method that aims to measure BP without using a cuff. In our previous article, we reported the development of a simple cuffless technique based on the haemodynamic expression, using only pulse rate (PR) and modified normalized pulse volume (mNPV) that can be measured using only a smartphone. The stressor used in our previous article was the cardiac-dominant pattern (mental arithmetic); however, here we have experimented with another stressor, namely, a vascular-dominant pattern in a cold pressor test, to verify this theory in 7 healthy young males and 6 healthy young females (N = 22). As a result, the mean arterial pressure accuracy was improved (r = 0.727) compared with that achieved in the previous study.

KW - Circulatory equation

KW - Cuffless blood pressure

KW - Heamodynamic

UR - http://www.scopus.com/inward/record.url?scp=85075859782&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85075859782&partnerID=8YFLogxK

U2 - 10.1007/978-3-030-31635-8_105

DO - 10.1007/978-3-030-31635-8_105

M3 - Conference contribution

AN - SCOPUS:85075859782

SN - 9783030316341

T3 - IFMBE Proceedings

SP - 874

EP - 877

BT - 15th Mediterranean Conference on Medical and Biological Engineering and Computing – MEDICON 2019 - Proceedings of MEDICON 2019

A2 - Henriques, Jorge

A2 - de Carvalho, Paulo

A2 - Neves, Nuno

PB - Springer

ER -