Decay of trapped magnetic field in HTS bulk caused by application of AC magnetic field

K. Yamagishi, J. Ogawa, O. Tsukamoto, M. Murakami, M. Tomita

研究成果: Conference article査読

35 被引用数 (Scopus)

抄録

In our previous work it was observed that trapped magnetic field in a YBCO bulk was decayed and even erased by application of AC external field whose amplitude was much smaller than the peak value of the trapped magnetic field. To study a reason for decay we investigated temperature rise of a YBCO bulk subject to the AC external magnetic field by use of thermocouples. A case was observed that the temperature rise of the bulk reached almost the critical temperature. This result shows that the decay of the trapped magnetic field was related to the temperature rise due to AC losses in the bulk.

本文言語English
ページ(範囲)659-663
ページ数5
ジャーナルPhysica C: Superconductivity and its applications
392-396
PART 1
DOI
出版ステータスPublished - 2003 10月 1
外部発表はい
イベントProceedings of the 15th International Symposium on Superconduc - Yokohama, Japan
継続期間: 2002 11月 112002 11月 13

ASJC Scopus subject areas

  • 電子材料、光学材料、および磁性材料
  • 凝縮系物理学
  • エネルギー工学および電力技術
  • 電子工学および電気工学

フィンガープリント