Design of upper limb patient simulator

C. Z. Noor Ayuni, Takashi Komeda, Cheng Yee Low

研究成果: Conference contribution

10 引用 (Scopus)

抄録

Spasticity is one of the muscle diseases in upper limb that is often seen in the patients of stroke and shoulder paralyzed. The disease occur when the patients central nerve is damaged, leading the patients having resistance in the joint when they tries to move it. In the area of orthopedics and rehabilitation, it has become essential to study the characteristics of human joint and muscle diseases. In this paper, an experiment to measure the characteristics of the disease was conducted and the data is used to reproduce the symptoms of spasticity in an upper limb patient simulator. The developed patient simulator is built with the joint and three bones of human arm: humerus, radius and ulna and is evaluated in term of reproducibility of the spasticity stiffness by two experiences physiotherapist.

元の言語English
ホスト出版物のタイトルProcedia Engineering
出版者Elsevier Ltd
ページ1374-1378
ページ数5
41
DOI
出版物ステータスPublished - 2012
イベント2nd International Symposium on Robotics and Intelligent Sensors 2012, IRIS 2012 - Kuching, Sarawak, Malaysia
継続期間: 2012 9 42012 9 6

Other

Other2nd International Symposium on Robotics and Intelligent Sensors 2012, IRIS 2012
Malaysia
Kuching, Sarawak
期間12/9/412/9/6

Fingerprint

Simulators
Muscle
Orthopedics
Patient rehabilitation
Bone
Stiffness
Experiments

ASJC Scopus subject areas

  • Engineering(all)

これを引用

Noor Ayuni, C. Z., Komeda, T., & Low, C. Y. (2012). Design of upper limb patient simulator. : Procedia Engineering (巻 41, pp. 1374-1378). Elsevier Ltd. https://doi.org/10.1016/j.proeng.2012.07.324

Design of upper limb patient simulator. / Noor Ayuni, C. Z.; Komeda, Takashi; Low, Cheng Yee.

Procedia Engineering. 巻 41 Elsevier Ltd, 2012. p. 1374-1378.

研究成果: Conference contribution

Noor Ayuni, CZ, Komeda, T & Low, CY 2012, Design of upper limb patient simulator. : Procedia Engineering. 巻. 41, Elsevier Ltd, pp. 1374-1378, 2nd International Symposium on Robotics and Intelligent Sensors 2012, IRIS 2012, Kuching, Sarawak, Malaysia, 12/9/4. https://doi.org/10.1016/j.proeng.2012.07.324
Noor Ayuni CZ, Komeda T, Low CY. Design of upper limb patient simulator. : Procedia Engineering. 巻 41. Elsevier Ltd. 2012. p. 1374-1378 https://doi.org/10.1016/j.proeng.2012.07.324
Noor Ayuni, C. Z. ; Komeda, Takashi ; Low, Cheng Yee. / Design of upper limb patient simulator. Procedia Engineering. 巻 41 Elsevier Ltd, 2012. pp. 1374-1378
@inproceedings{24c11e4e05f54f3aa8717aa182935846,
title = "Design of upper limb patient simulator",
abstract = "Spasticity is one of the muscle diseases in upper limb that is often seen in the patients of stroke and shoulder paralyzed. The disease occur when the patients central nerve is damaged, leading the patients having resistance in the joint when they tries to move it. In the area of orthopedics and rehabilitation, it has become essential to study the characteristics of human joint and muscle diseases. In this paper, an experiment to measure the characteristics of the disease was conducted and the data is used to reproduce the symptoms of spasticity in an upper limb patient simulator. The developed patient simulator is built with the joint and three bones of human arm: humerus, radius and ulna and is evaluated in term of reproducibility of the spasticity stiffness by two experiences physiotherapist.",
keywords = "Patient simulator, Rehabilitation, Spasticity, Upper limb disorder",
author = "{Noor Ayuni}, {C. Z.} and Takashi Komeda and Low, {Cheng Yee}",
year = "2012",
doi = "10.1016/j.proeng.2012.07.324",
language = "English",
volume = "41",
pages = "1374--1378",
booktitle = "Procedia Engineering",
publisher = "Elsevier Ltd",

}

TY - GEN

T1 - Design of upper limb patient simulator

AU - Noor Ayuni, C. Z.

AU - Komeda, Takashi

AU - Low, Cheng Yee

PY - 2012

Y1 - 2012

N2 - Spasticity is one of the muscle diseases in upper limb that is often seen in the patients of stroke and shoulder paralyzed. The disease occur when the patients central nerve is damaged, leading the patients having resistance in the joint when they tries to move it. In the area of orthopedics and rehabilitation, it has become essential to study the characteristics of human joint and muscle diseases. In this paper, an experiment to measure the characteristics of the disease was conducted and the data is used to reproduce the symptoms of spasticity in an upper limb patient simulator. The developed patient simulator is built with the joint and three bones of human arm: humerus, radius and ulna and is evaluated in term of reproducibility of the spasticity stiffness by two experiences physiotherapist.

AB - Spasticity is one of the muscle diseases in upper limb that is often seen in the patients of stroke and shoulder paralyzed. The disease occur when the patients central nerve is damaged, leading the patients having resistance in the joint when they tries to move it. In the area of orthopedics and rehabilitation, it has become essential to study the characteristics of human joint and muscle diseases. In this paper, an experiment to measure the characteristics of the disease was conducted and the data is used to reproduce the symptoms of spasticity in an upper limb patient simulator. The developed patient simulator is built with the joint and three bones of human arm: humerus, radius and ulna and is evaluated in term of reproducibility of the spasticity stiffness by two experiences physiotherapist.

KW - Patient simulator

KW - Rehabilitation

KW - Spasticity

KW - Upper limb disorder

UR - http://www.scopus.com/inward/record.url?scp=84886232786&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=84886232786&partnerID=8YFLogxK

U2 - 10.1016/j.proeng.2012.07.324

DO - 10.1016/j.proeng.2012.07.324

M3 - Conference contribution

AN - SCOPUS:84886232786

VL - 41

SP - 1374

EP - 1378

BT - Procedia Engineering

PB - Elsevier Ltd