Development of a respiration monitoring sensor for diving worker

Ryotaro Nakazumi, Makito Inoue, Takashi Yoshimi, Shozo Fuchiyama, Hiroshi Tsuchiya

研究成果: Conference contribution

抄録

The demand of diving works is very increasing for investigation, construction and maintenance. The environments of them are very severe and dangerous, so the grasping of diving workers' conditions and keeping their safety is a very important issue. Some respiration monitoring sensors were developed for diving workers, but they have a risk of occlusion of the suction tube. Then, we propose a new sensor which is mounted to the expiratory side of the diving mask for the improvement of its safety. In this study, we confirm the effectiveness of the basic performance of the proposed new sensor through experiments.

元の言語English
ホスト出版物のタイトル2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017
出版者Institute of Electrical and Electronics Engineers Inc.
ページ206-208
ページ数3
2017-November
ISBN(電子版)9784907764579
DOI
出版物ステータスPublished - 2017 11 10
イベント56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017 - Kanazawa, Japan
継続期間: 2017 9 192017 9 22

Other

Other56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017
Japan
Kanazawa
期間17/9/1917/9/22

Fingerprint

respiration
Monitoring
sensors
Sensors
safety
Masks
occlusion
suction
maintenance
masks
tubes
Experiments

ASJC Scopus subject areas

  • Computer Science Applications
  • Control and Optimization
  • Control and Systems Engineering
  • Instrumentation

これを引用

Nakazumi, R., Inoue, M., Yoshimi, T., Fuchiyama, S., & Tsuchiya, H. (2017). Development of a respiration monitoring sensor for diving worker. : 2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017 (巻 2017-November, pp. 206-208). Institute of Electrical and Electronics Engineers Inc.. https://doi.org/10.23919/SICE.2017.8105779

Development of a respiration monitoring sensor for diving worker. / Nakazumi, Ryotaro; Inoue, Makito; Yoshimi, Takashi; Fuchiyama, Shozo; Tsuchiya, Hiroshi.

2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017. 巻 2017-November Institute of Electrical and Electronics Engineers Inc., 2017. p. 206-208.

研究成果: Conference contribution

Nakazumi, R, Inoue, M, Yoshimi, T, Fuchiyama, S & Tsuchiya, H 2017, Development of a respiration monitoring sensor for diving worker. : 2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017. 巻. 2017-November, Institute of Electrical and Electronics Engineers Inc., pp. 206-208, 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017, Kanazawa, Japan, 17/9/19. https://doi.org/10.23919/SICE.2017.8105779
Nakazumi R, Inoue M, Yoshimi T, Fuchiyama S, Tsuchiya H. Development of a respiration monitoring sensor for diving worker. : 2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017. 巻 2017-November. Institute of Electrical and Electronics Engineers Inc. 2017. p. 206-208 https://doi.org/10.23919/SICE.2017.8105779
Nakazumi, Ryotaro ; Inoue, Makito ; Yoshimi, Takashi ; Fuchiyama, Shozo ; Tsuchiya, Hiroshi. / Development of a respiration monitoring sensor for diving worker. 2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017. 巻 2017-November Institute of Electrical and Electronics Engineers Inc., 2017. pp. 206-208
@inproceedings{0e967fd9bee34ff58e4a6f9ed0ecde39,
title = "Development of a respiration monitoring sensor for diving worker",
abstract = "The demand of diving works is very increasing for investigation, construction and maintenance. The environments of them are very severe and dangerous, so the grasping of diving workers' conditions and keeping their safety is a very important issue. Some respiration monitoring sensors were developed for diving workers, but they have a risk of occlusion of the suction tube. Then, we propose a new sensor which is mounted to the expiratory side of the diving mask for the improvement of its safety. In this study, we confirm the effectiveness of the basic performance of the proposed new sensor through experiments.",
keywords = "Diving worker, Expiration, Respiration monitoring sensor, Underwater",
author = "Ryotaro Nakazumi and Makito Inoue and Takashi Yoshimi and Shozo Fuchiyama and Hiroshi Tsuchiya",
year = "2017",
month = "11",
day = "10",
doi = "10.23919/SICE.2017.8105779",
language = "English",
volume = "2017-November",
pages = "206--208",
booktitle = "2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017",
publisher = "Institute of Electrical and Electronics Engineers Inc.",

}

TY - GEN

T1 - Development of a respiration monitoring sensor for diving worker

AU - Nakazumi, Ryotaro

AU - Inoue, Makito

AU - Yoshimi, Takashi

AU - Fuchiyama, Shozo

AU - Tsuchiya, Hiroshi

PY - 2017/11/10

Y1 - 2017/11/10

N2 - The demand of diving works is very increasing for investigation, construction and maintenance. The environments of them are very severe and dangerous, so the grasping of diving workers' conditions and keeping their safety is a very important issue. Some respiration monitoring sensors were developed for diving workers, but they have a risk of occlusion of the suction tube. Then, we propose a new sensor which is mounted to the expiratory side of the diving mask for the improvement of its safety. In this study, we confirm the effectiveness of the basic performance of the proposed new sensor through experiments.

AB - The demand of diving works is very increasing for investigation, construction and maintenance. The environments of them are very severe and dangerous, so the grasping of diving workers' conditions and keeping their safety is a very important issue. Some respiration monitoring sensors were developed for diving workers, but they have a risk of occlusion of the suction tube. Then, we propose a new sensor which is mounted to the expiratory side of the diving mask for the improvement of its safety. In this study, we confirm the effectiveness of the basic performance of the proposed new sensor through experiments.

KW - Diving worker

KW - Expiration

KW - Respiration monitoring sensor

KW - Underwater

UR - http://www.scopus.com/inward/record.url?scp=85044205789&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85044205789&partnerID=8YFLogxK

U2 - 10.23919/SICE.2017.8105779

DO - 10.23919/SICE.2017.8105779

M3 - Conference contribution

AN - SCOPUS:85044205789

VL - 2017-November

SP - 206

EP - 208

BT - 2017 56th Annual Conference of the Society of Instrument and Control Engineers of Japan, SICE 2017

PB - Institute of Electrical and Electronics Engineers Inc.

ER -