We studied a variable-capacitance-type electrostatic generator that could potentially be used to permanently supply electrical energy to an apperatus for in vivo use such as a cardiac pacemaker. The generating system consists of a battery for supplying electric charge, a variable capacitor for energy conversion, a capacitor for electrical energy storage and two rectifiers. A honeycomb-type variable capacitor whose capacitance varies from 54 to 290 nF was created. It was possible to generate a maximum electrical energy of approximately 14.3 μJ/cycle. We found that the electrical energy for driving a cadiac pacemaker can be generated by using the honeycomb-type variable capacitor with higher capacitance.

元の言語English
ページ(範囲)491-496
ページ数6
ジャーナルJapanese Journal of Artificial Organs
28
発行部数2
出版物ステータスPublished - 1999
外部発表Yes

ASJC Scopus subject areas

  • Biophysics

これを引用

Tashiro, R., Kabei, N., Tsuchiya, K., Katayama, K., Ishizuka, Y., & Tsuboi, F. (1999). Development of an electrostatic generator that harnesses the motion of a living body - Fundamental study. Japanese Journal of Artificial Organs, 28(2), 491-496.

Development of an electrostatic generator that harnesses the motion of a living body - Fundamental study. / Tashiro, R.; Kabei, N.; Tsuchiya, K.; Katayama, K.; Ishizuka, Y.; Tsuboi, F.

:: Japanese Journal of Artificial Organs, 巻 28, 番号 2, 1999, p. 491-496.

研究成果: Article

Tashiro, R, Kabei, N, Tsuchiya, K, Katayama, K, Ishizuka, Y & Tsuboi, F 1999, 'Development of an electrostatic generator that harnesses the motion of a living body - Fundamental study', Japanese Journal of Artificial Organs, 巻. 28, 番号 2, pp. 491-496.
Tashiro, R. ; Kabei, N. ; Tsuchiya, K. ; Katayama, K. ; Ishizuka, Y. ; Tsuboi, F. / Development of an electrostatic generator that harnesses the motion of a living body - Fundamental study. :: Japanese Journal of Artificial Organs. 1999 ; 巻 28, 番号 2. pp. 491-496.
@article{dd1e265e0a8547bea276943aa2950bdb,
title = "Development of an electrostatic generator that harnesses the motion of a living body - Fundamental study",
abstract = "We studied a variable-capacitance-type electrostatic generator that could potentially be used to permanently supply electrical energy to an apperatus for in vivo use such as a cardiac pacemaker. The generating system consists of a battery for supplying electric charge, a variable capacitor for energy conversion, a capacitor for electrical energy storage and two rectifiers. A honeycomb-type variable capacitor whose capacitance varies from 54 to 290 nF was created. It was possible to generate a maximum electrical energy of approximately 14.3 μJ/cycle. We found that the electrical energy for driving a cadiac pacemaker can be generated by using the honeycomb-type variable capacitor with higher capacitance.",
keywords = "Cardiac pacemaker, Electrostatic, Generator, Micromachine",
author = "R. Tashiro and N. Kabei and K. Tsuchiya and K. Katayama and Y. Ishizuka and F. Tsuboi",
year = "1999",
language = "English",
volume = "28",
pages = "491--496",
journal = "Japanese Journal of Artificial Organs",
issn = "0300-0818",
publisher = "Japanese Society for Artificial Organs and Tissues",
number = "2",

}

TY - JOUR

T1 - Development of an electrostatic generator that harnesses the motion of a living body - Fundamental study

AU - Tashiro, R.

AU - Kabei, N.

AU - Tsuchiya, K.

AU - Katayama, K.

AU - Ishizuka, Y.

AU - Tsuboi, F.

PY - 1999

Y1 - 1999

N2 - We studied a variable-capacitance-type electrostatic generator that could potentially be used to permanently supply electrical energy to an apperatus for in vivo use such as a cardiac pacemaker. The generating system consists of a battery for supplying electric charge, a variable capacitor for energy conversion, a capacitor for electrical energy storage and two rectifiers. A honeycomb-type variable capacitor whose capacitance varies from 54 to 290 nF was created. It was possible to generate a maximum electrical energy of approximately 14.3 μJ/cycle. We found that the electrical energy for driving a cadiac pacemaker can be generated by using the honeycomb-type variable capacitor with higher capacitance.

AB - We studied a variable-capacitance-type electrostatic generator that could potentially be used to permanently supply electrical energy to an apperatus for in vivo use such as a cardiac pacemaker. The generating system consists of a battery for supplying electric charge, a variable capacitor for energy conversion, a capacitor for electrical energy storage and two rectifiers. A honeycomb-type variable capacitor whose capacitance varies from 54 to 290 nF was created. It was possible to generate a maximum electrical energy of approximately 14.3 μJ/cycle. We found that the electrical energy for driving a cadiac pacemaker can be generated by using the honeycomb-type variable capacitor with higher capacitance.

KW - Cardiac pacemaker

KW - Electrostatic

KW - Generator

KW - Micromachine

UR - http://www.scopus.com/inward/record.url?scp=0032983201&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0032983201&partnerID=8YFLogxK

M3 - Article

AN - SCOPUS:0032983201

VL - 28

SP - 491

EP - 496

JO - Japanese Journal of Artificial Organs

JF - Japanese Journal of Artificial Organs

SN - 0300-0818

IS - 2

ER -