The BEST cogeneration study sub working group has been developing simulation models related to cogeneration systems (CGS) since 2008 to simulate the system including CGS using the BEST program. This paper describes simulation case studies of CGS in a hotel which has high hot water loads using BEST for energy conservation standards revised in 2013 (BEST program 2013) and summarizes input parameters about CGS and utilization of exhaust heat from CGS equipment. Simulation case study results show that exhaust heat is used efficiently for hot water loads in most cases, and it would be better to use exhaust heat to hot water load than cooling/heating load.

元の言語English
ホスト出版物のタイトル24th IIR International Congress of Refrigeration, ICR 2015
出版者International Institute of Refrigeration
ページ4158-4164
ページ数7
ISBN(電子版)9782362150128
DOI
出版物ステータスPublished - 2015
イベント24th IIR International Congress of Refrigeration, ICR 2015 - Yokohama, Japan
継続期間: 2015 8 162015 8 22

Other

Other24th IIR International Congress of Refrigeration, ICR 2015
Japan
Yokohama
期間15/8/1615/8/22

Fingerprint

cogeneration
Hotels
Water
Ventilation exhausts
simulation
heat
energy
Energy conservation
water
Cooling
Heating
energy conservation
Hot Temperature
cooling
heating

ASJC Scopus subject areas

  • Control and Systems Engineering
  • Electrical and Electronic Engineering
  • Mechanical Engineering
  • Condensed Matter Physics

これを引用

Satoh, M., Tsujimaru, N., Murakami, S., Akimoto, T., Ishino, H., Sasajima, K., ... Yuasa, R. (2015). Development of an integrated energy simulation tool for buildings and MEP systems, the BEST simulation study of cogeneration system in hotels using BEST program 2013. : 24th IIR International Congress of Refrigeration, ICR 2015 (pp. 4158-4164). International Institute of Refrigeration. https://doi.org/10.18462/iir.icr.2015.0222

Development of an integrated energy simulation tool for buildings and MEP systems, the BEST simulation study of cogeneration system in hotels using BEST program 2013. / Satoh, Makoto; Tsujimaru, Norie; Murakami, Shuzo; Akimoto, Takashi; Ishino, Hisaya; Sasajima, Kenichi; Nohara, Fumio; Ninomiya, Hiroshi; Fujii, Tatsuo; Kuzuki, Ryota; Yuasa, Ritsuko.

24th IIR International Congress of Refrigeration, ICR 2015. International Institute of Refrigeration, 2015. p. 4158-4164.

研究成果: Conference contribution

Satoh, M, Tsujimaru, N, Murakami, S, Akimoto, T, Ishino, H, Sasajima, K, Nohara, F, Ninomiya, H, Fujii, T, Kuzuki, R & Yuasa, R 2015, Development of an integrated energy simulation tool for buildings and MEP systems, the BEST simulation study of cogeneration system in hotels using BEST program 2013. : 24th IIR International Congress of Refrigeration, ICR 2015. International Institute of Refrigeration, pp. 4158-4164, 24th IIR International Congress of Refrigeration, ICR 2015, Yokohama, Japan, 15/8/16. https://doi.org/10.18462/iir.icr.2015.0222
Satoh M, Tsujimaru N, Murakami S, Akimoto T, Ishino H, Sasajima K その他. Development of an integrated energy simulation tool for buildings and MEP systems, the BEST simulation study of cogeneration system in hotels using BEST program 2013. : 24th IIR International Congress of Refrigeration, ICR 2015. International Institute of Refrigeration. 2015. p. 4158-4164 https://doi.org/10.18462/iir.icr.2015.0222
Satoh, Makoto ; Tsujimaru, Norie ; Murakami, Shuzo ; Akimoto, Takashi ; Ishino, Hisaya ; Sasajima, Kenichi ; Nohara, Fumio ; Ninomiya, Hiroshi ; Fujii, Tatsuo ; Kuzuki, Ryota ; Yuasa, Ritsuko. / Development of an integrated energy simulation tool for buildings and MEP systems, the BEST simulation study of cogeneration system in hotels using BEST program 2013. 24th IIR International Congress of Refrigeration, ICR 2015. International Institute of Refrigeration, 2015. pp. 4158-4164
@inproceedings{052f2edfac034838930b78f058303708,
title = "Development of an integrated energy simulation tool for buildings and MEP systems, the BEST simulation study of cogeneration system in hotels using BEST program 2013",
abstract = "The BEST cogeneration study sub working group has been developing simulation models related to cogeneration systems (CGS) since 2008 to simulate the system including CGS using the BEST program. This paper describes simulation case studies of CGS in a hotel which has high hot water loads using BEST for energy conservation standards revised in 2013 (BEST program 2013) and summarizes input parameters about CGS and utilization of exhaust heat from CGS equipment. Simulation case study results show that exhaust heat is used efficiently for hot water loads in most cases, and it would be better to use exhaust heat to hot water load than cooling/heating load.",
author = "Makoto Satoh and Norie Tsujimaru and Shuzo Murakami and Takashi Akimoto and Hisaya Ishino and Kenichi Sasajima and Fumio Nohara and Hiroshi Ninomiya and Tatsuo Fujii and Ryota Kuzuki and Ritsuko Yuasa",
year = "2015",
doi = "10.18462/iir.icr.2015.0222",
language = "English",
pages = "4158--4164",
booktitle = "24th IIR International Congress of Refrigeration, ICR 2015",
publisher = "International Institute of Refrigeration",

}

TY - GEN

T1 - Development of an integrated energy simulation tool for buildings and MEP systems, the BEST simulation study of cogeneration system in hotels using BEST program 2013

AU - Satoh, Makoto

AU - Tsujimaru, Norie

AU - Murakami, Shuzo

AU - Akimoto, Takashi

AU - Ishino, Hisaya

AU - Sasajima, Kenichi

AU - Nohara, Fumio

AU - Ninomiya, Hiroshi

AU - Fujii, Tatsuo

AU - Kuzuki, Ryota

AU - Yuasa, Ritsuko

PY - 2015

Y1 - 2015

N2 - The BEST cogeneration study sub working group has been developing simulation models related to cogeneration systems (CGS) since 2008 to simulate the system including CGS using the BEST program. This paper describes simulation case studies of CGS in a hotel which has high hot water loads using BEST for energy conservation standards revised in 2013 (BEST program 2013) and summarizes input parameters about CGS and utilization of exhaust heat from CGS equipment. Simulation case study results show that exhaust heat is used efficiently for hot water loads in most cases, and it would be better to use exhaust heat to hot water load than cooling/heating load.

AB - The BEST cogeneration study sub working group has been developing simulation models related to cogeneration systems (CGS) since 2008 to simulate the system including CGS using the BEST program. This paper describes simulation case studies of CGS in a hotel which has high hot water loads using BEST for energy conservation standards revised in 2013 (BEST program 2013) and summarizes input parameters about CGS and utilization of exhaust heat from CGS equipment. Simulation case study results show that exhaust heat is used efficiently for hot water loads in most cases, and it would be better to use exhaust heat to hot water load than cooling/heating load.

UR - http://www.scopus.com/inward/record.url?scp=85016763299&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=85016763299&partnerID=8YFLogxK

U2 - 10.18462/iir.icr.2015.0222

DO - 10.18462/iir.icr.2015.0222

M3 - Conference contribution

AN - SCOPUS:85016763299

SP - 4158

EP - 4164

BT - 24th IIR International Congress of Refrigeration, ICR 2015

PB - International Institute of Refrigeration

ER -