Evaluation of the measurement of AC transport current loss in assembled HTS tapes using a pick-up loop

J. Ogawa, S. Fukui, T. Oka, M. Yamaguchi, T. Sato, K. Yamaya, T. Hamada, H. Tanaka

研究成果: Article査読

2 被引用数 (Scopus)

抄録

In this study, we investigated AC transport current measurement using a pick-up loop. In a single HTS tape the correction factors for different pick-up loop shapes correspond with the experimental and numerical results. In an assembled conductor, we experimentally investigated the difference in the correction factors for the serial and parallel connected transport current in each HTS tape. In parallel mode, the correction factor has a constant value against the total transport current, while in serial mode the correction factor varies. These results can be explained by the relation between the transport current distribution in each HTS tape and the position of the pick-up loops.

本文言語English
ページ(範囲)1159-1162
ページ数4
ジャーナルPhysica C: Superconductivity and its applications
463-465
SUPPL.
DOI
出版ステータスPublished - 2007 10月 1
外部発表はい

ASJC Scopus subject areas

  • 電子材料、光学材料、および磁性材料
  • 凝縮系物理学
  • エネルギー工学および電力技術
  • 電子工学および電気工学