Image correction method for the chemical imaging sensor

Ko ichiro Miyamoto, Yuri Sugawara, Shinichiro Kanoh, Tatsuo Yoshinobu, Torsten Wagner, Michael J. Schöning

研究成果: Article

18 引用 (Scopus)

抄録

The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate.

元の言語English
ページ(範囲)344-348
ページ数5
ジャーナルSensors and Actuators, B: Chemical
144
発行部数2
DOI
出版物ステータスPublished - 2010 2 17
外部発表Yes

Fingerprint

Imaging techniques
sensors
Sensors
Semiconductor materials
Chemical sensors
Spatial distribution
Contamination
nonuniformity
artifacts
Defects
spatial distribution
contamination
Substrates
defects

ASJC Scopus subject areas

  • Instrumentation
  • Materials Chemistry
  • Surfaces, Coatings and Films
  • Metals and Alloys
  • Electronic, Optical and Magnetic Materials
  • Condensed Matter Physics
  • Electrical and Electronic Engineering

これを引用

Miyamoto, K. I., Sugawara, Y., Kanoh, S., Yoshinobu, T., Wagner, T., & Schöning, M. J. (2010). Image correction method for the chemical imaging sensor. Sensors and Actuators, B: Chemical, 144(2), 344-348. https://doi.org/10.1016/j.snb.2008.10.069

Image correction method for the chemical imaging sensor. / Miyamoto, Ko ichiro; Sugawara, Yuri; Kanoh, Shinichiro; Yoshinobu, Tatsuo; Wagner, Torsten; Schöning, Michael J.

:: Sensors and Actuators, B: Chemical, 巻 144, 番号 2, 17.02.2010, p. 344-348.

研究成果: Article

Miyamoto, KI, Sugawara, Y, Kanoh, S, Yoshinobu, T, Wagner, T & Schöning, MJ 2010, 'Image correction method for the chemical imaging sensor', Sensors and Actuators, B: Chemical, 巻. 144, 番号 2, pp. 344-348. https://doi.org/10.1016/j.snb.2008.10.069
Miyamoto, Ko ichiro ; Sugawara, Yuri ; Kanoh, Shinichiro ; Yoshinobu, Tatsuo ; Wagner, Torsten ; Schöning, Michael J. / Image correction method for the chemical imaging sensor. :: Sensors and Actuators, B: Chemical. 2010 ; 巻 144, 番号 2. pp. 344-348.
@article{7260dd360f014a929d68321114ecb38e,
title = "Image correction method for the chemical imaging sensor",
abstract = "The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate.",
keywords = "Calibration, Chemical imaging sensor, Image correction, Light-addressable potentiometric sensor (LAPS)",
author = "Miyamoto, {Ko ichiro} and Yuri Sugawara and Shinichiro Kanoh and Tatsuo Yoshinobu and Torsten Wagner and Sch{\"o}ning, {Michael J.}",
year = "2010",
month = "2",
day = "17",
doi = "10.1016/j.snb.2008.10.069",
language = "English",
volume = "144",
pages = "344--348",
journal = "Sensors and Actuators, B: Chemical",
issn = "0925-4005",
publisher = "Elsevier",
number = "2",

}

TY - JOUR

T1 - Image correction method for the chemical imaging sensor

AU - Miyamoto, Ko ichiro

AU - Sugawara, Yuri

AU - Kanoh, Shinichiro

AU - Yoshinobu, Tatsuo

AU - Wagner, Torsten

AU - Schöning, Michael J.

PY - 2010/2/17

Y1 - 2010/2/17

N2 - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate.

AB - The chemical imaging sensor is a semiconductor-based chemical sensor that can visualize the spatial distribution of chemical species. For the practical application of this sensor, artifacts in the chemical images due to defects of the semiconductor substrate and contamination of the sensing surface etc. have been a major problem. An image correction method was developed to eliminate the influence of nonuniformity of individual sensor plate.

KW - Calibration

KW - Chemical imaging sensor

KW - Image correction

KW - Light-addressable potentiometric sensor (LAPS)

UR - http://www.scopus.com/inward/record.url?scp=75749088940&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=75749088940&partnerID=8YFLogxK

U2 - 10.1016/j.snb.2008.10.069

DO - 10.1016/j.snb.2008.10.069

M3 - Article

AN - SCOPUS:75749088940

VL - 144

SP - 344

EP - 348

JO - Sensors and Actuators, B: Chemical

JF - Sensors and Actuators, B: Chemical

SN - 0925-4005

IS - 2

ER -