抄録
The function of the magnetocaloric heat pump with an active magnetic regenerator (AMR) cycle is based on a magnetocaloric effect (MCE). In the process of the AMR cycle, the range within which the magnetocaloric material (MCM) exhibits an MCE is narrow near its Curie point. Therefore, there is only a narrow temperature span in the case of an AMR with a single MCM. In order to solve this problem, an AMR system with material layers was used, based on the arrangement of a couple of MCMs in the regenerator. Given that only a limited number of studies exist on the magnetocaloric heat pump using a material-layered system, the influence of the MCM properties on this heat pump is still unclear. Therefore, the refrigeration capacity and the temperature span of the magnetocaloric heat pump using the material-layered system are numerically evaluated in this study in order to obtain guidance for the system design. These results are compared with those gotten extracted for the magnetocaloric heat pump of the single MCM.
本文言語 | English |
---|---|
ホスト出版物のタイトル | 24th IIR International Congress of Refrigeration, ICR 2015 |
出版社 | International Institute of Refrigeration |
ページ | 942-949 |
ページ数 | 8 |
ISBN(電子版) | 9782362150128 |
DOI | |
出版ステータス | Published - 2015 |
外部発表 | はい |
イベント | 24th IIR International Congress of Refrigeration, ICR 2015 - Yokohama, Japan 継続期間: 2015 8月 16 → 2015 8月 22 |
Other
Other | 24th IIR International Congress of Refrigeration, ICR 2015 |
---|---|
国/地域 | Japan |
City | Yokohama |
Period | 15/8/16 → 15/8/22 |
ASJC Scopus subject areas
- 制御およびシステム工学
- 電子工学および電気工学
- 機械工学
- 凝縮系物理学