Tele-virtual surgery with sharing tactile sensations between Japan and Germany

A. Hattori, N. Suzuki, S. Suzuki, A. Takatsu, M. P. Baur, A. Hirner, S. Takahashi, S. Kobayashi, Y. Yamazaki, Yoshitaka Adachi, T. Kumano, A. Ikemoto

研究成果: Conference contribution

1 引用 (Scopus)

抄録

In this paper, we report the results of a tele-virtual surgery experiment between Japan and Germany. In this experiment, we tried to use a 1ch ISDN line. Participants at each location employed two graphic workstations for the surgical simulation and tele-conference. Each workstation had a force feedback device. These devices conveyed tactile sensations to the surgeons during the virtual surgical operation. A simulated hepatectomy was chosen for the experiment. Surgeons in each location palpated the patient's abdominal skin, and made electrical scalpel incisions and widened the incision line by using surgical tools in virtual space. We conducted an experiment in which two surgeons simulated virtual surgery while sharing identical tactile sensations over a long distance. It was possible to obtain real-time tele-virtual surgery without a large capacity communication infrastructure.

元の言語English
ホスト出版物のタイトルAnnual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings
編集者J.D. Enderle
ページ2423-2425
ページ数3
4
出版物ステータスPublished - 2000
外部発表Yes
イベント22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society - Chicago, IL, United States
継続期間: 2000 7 232000 7 28

Other

Other22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society
United States
Chicago, IL
期間00/7/2300/7/28

Fingerprint

Surgery
Experiments
Voice/data communication systems
Skin
Feedback
Communication

ASJC Scopus subject areas

  • Bioengineering

これを引用

Hattori, A., Suzuki, N., Suzuki, S., Takatsu, A., Baur, M. P., Hirner, A., ... Ikemoto, A. (2000). Tele-virtual surgery with sharing tactile sensations between Japan and Germany. : J. D. Enderle (版), Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings (巻 4, pp. 2423-2425)

Tele-virtual surgery with sharing tactile sensations between Japan and Germany. / Hattori, A.; Suzuki, N.; Suzuki, S.; Takatsu, A.; Baur, M. P.; Hirner, A.; Takahashi, S.; Kobayashi, S.; Yamazaki, Y.; Adachi, Yoshitaka; Kumano, T.; Ikemoto, A.

Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 版 / J.D. Enderle. 巻 4 2000. p. 2423-2425.

研究成果: Conference contribution

Hattori, A, Suzuki, N, Suzuki, S, Takatsu, A, Baur, MP, Hirner, A, Takahashi, S, Kobayashi, S, Yamazaki, Y, Adachi, Y, Kumano, T & Ikemoto, A 2000, Tele-virtual surgery with sharing tactile sensations between Japan and Germany. : JD Enderle (版), Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 巻. 4, pp. 2423-2425, 22nd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, Chicago, IL, United States, 00/7/23.
Hattori A, Suzuki N, Suzuki S, Takatsu A, Baur MP, Hirner A その他. Tele-virtual surgery with sharing tactile sensations between Japan and Germany. : Enderle JD, 編集者, Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 巻 4. 2000. p. 2423-2425
Hattori, A. ; Suzuki, N. ; Suzuki, S. ; Takatsu, A. ; Baur, M. P. ; Hirner, A. ; Takahashi, S. ; Kobayashi, S. ; Yamazaki, Y. ; Adachi, Yoshitaka ; Kumano, T. ; Ikemoto, A. / Tele-virtual surgery with sharing tactile sensations between Japan and Germany. Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings. 編集者 / J.D. Enderle. 巻 4 2000. pp. 2423-2425
@inproceedings{554fa1a224cb4d0f924e1285aa9fd6a7,
title = "Tele-virtual surgery with sharing tactile sensations between Japan and Germany",
abstract = "In this paper, we report the results of a tele-virtual surgery experiment between Japan and Germany. In this experiment, we tried to use a 1ch ISDN line. Participants at each location employed two graphic workstations for the surgical simulation and tele-conference. Each workstation had a force feedback device. These devices conveyed tactile sensations to the surgeons during the virtual surgical operation. A simulated hepatectomy was chosen for the experiment. Surgeons in each location palpated the patient's abdominal skin, and made electrical scalpel incisions and widened the incision line by using surgical tools in virtual space. We conducted an experiment in which two surgeons simulated virtual surgery while sharing identical tactile sensations over a long distance. It was possible to obtain real-time tele-virtual surgery without a large capacity communication infrastructure.",
keywords = "Force feedback device, Surgical simulation, Tele-virtual surgery, Virtual reality",
author = "A. Hattori and N. Suzuki and S. Suzuki and A. Takatsu and Baur, {M. P.} and A. Hirner and S. Takahashi and S. Kobayashi and Y. Yamazaki and Yoshitaka Adachi and T. Kumano and A. Ikemoto",
year = "2000",
language = "English",
volume = "4",
pages = "2423--2425",
editor = "J.D. Enderle",
booktitle = "Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings",

}

TY - GEN

T1 - Tele-virtual surgery with sharing tactile sensations between Japan and Germany

AU - Hattori, A.

AU - Suzuki, N.

AU - Suzuki, S.

AU - Takatsu, A.

AU - Baur, M. P.

AU - Hirner, A.

AU - Takahashi, S.

AU - Kobayashi, S.

AU - Yamazaki, Y.

AU - Adachi, Yoshitaka

AU - Kumano, T.

AU - Ikemoto, A.

PY - 2000

Y1 - 2000

N2 - In this paper, we report the results of a tele-virtual surgery experiment between Japan and Germany. In this experiment, we tried to use a 1ch ISDN line. Participants at each location employed two graphic workstations for the surgical simulation and tele-conference. Each workstation had a force feedback device. These devices conveyed tactile sensations to the surgeons during the virtual surgical operation. A simulated hepatectomy was chosen for the experiment. Surgeons in each location palpated the patient's abdominal skin, and made electrical scalpel incisions and widened the incision line by using surgical tools in virtual space. We conducted an experiment in which two surgeons simulated virtual surgery while sharing identical tactile sensations over a long distance. It was possible to obtain real-time tele-virtual surgery without a large capacity communication infrastructure.

AB - In this paper, we report the results of a tele-virtual surgery experiment between Japan and Germany. In this experiment, we tried to use a 1ch ISDN line. Participants at each location employed two graphic workstations for the surgical simulation and tele-conference. Each workstation had a force feedback device. These devices conveyed tactile sensations to the surgeons during the virtual surgical operation. A simulated hepatectomy was chosen for the experiment. Surgeons in each location palpated the patient's abdominal skin, and made electrical scalpel incisions and widened the incision line by using surgical tools in virtual space. We conducted an experiment in which two surgeons simulated virtual surgery while sharing identical tactile sensations over a long distance. It was possible to obtain real-time tele-virtual surgery without a large capacity communication infrastructure.

KW - Force feedback device

KW - Surgical simulation

KW - Tele-virtual surgery

KW - Virtual reality

UR - http://www.scopus.com/inward/record.url?scp=0034445272&partnerID=8YFLogxK

UR - http://www.scopus.com/inward/citedby.url?scp=0034445272&partnerID=8YFLogxK

M3 - Conference contribution

AN - SCOPUS:0034445272

VL - 4

SP - 2423

EP - 2425

BT - Annual International Conference of the IEEE Engineering in Medicine and Biology - Proceedings

A2 - Enderle, J.D.

ER -